Siemens SIMATIC S7-1500 TM MFP Expired Pointer Dereference (CVE-2026-46125)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(506454);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/21");
script_cve_id("CVE-2026-46125");
script_name(english:"Siemens SIMATIC S7-1500 TM MFP Expired Pointer Dereference (CVE-2026-46125)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
wifi: mac80211: remove station if connection prep fails
If connection preparation fails for MLO connections, then the
interface is completely reset to non-MLD. In this case, we must
not keep the station since it's related to the link of the vif
being removed. Delete an existing station. Any 'new_sta' is
already being removed, so that doesn't need changes.
This fixes a use-after-free/double-free in debugfs if that's
enabled, because a vif going from MLD (and to MLD, but that's
not relevant here) recreates its entire debugfs.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:A/AC:L/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-46125");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(825);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
21 Oct 2026 00:00Current
5.9Medium risk
Vulners AI Score5.9
CVSS 3.16.8 - 8.8
EPSS0.00442
SSVC