Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-31704)

🗓️ 20 Oct 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 3 Views

Improper input validation in Linux kernel ksmbd allows u16 DACL size overflow.

Related
Refs
Code
ReporterTitlePublishedViews
Family
attackerkb
attackerkb
CVE-2026-31704
1 May 202613:56
–attackerkb
astralinux
AstraLinux
Astra Linux – Vulnerability in Linux 6.1
5 Oct 202611:39
–astralinux
bdu_fstec
BDU FSTEC
SMB Server Buffer Overflow DoS
10 Aug 202600:00
–bdu_fstec
cbl_mariner
CBLMariner
CVE-2026-31704 affecting package kernel for versions less than 6.6.137.1-2
9 May 202603:31
–cbl_mariner
cgr
Chainguard
CVE-2026-31704 vulnerabilities
8 May 202607:18
–cgr
circl
Circl
CVE-2026-31704
2 Jul 202605:51
–circl
cnnvd
CNNVD
Linux Kernel Security Vulnerabilities
1 May 202600:00
–cnnvd
cve
CVE
CVE-2026-31704
1 May 202613:56
–cve
cvelist
Cvelist
CVE-2026-31704 ksmbd: use check_add_overflow() to prevent u16 DACL size overflow
1 May 202613:56
–cvelist
debian
Debian
[SECURITY] [DLA 4665-1] linux security update
3 Jul 202618:38
–debian
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(506388);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/21");

  script_cve_id("CVE-2026-31704");

  script_name(english:"Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-31704)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:

ksmbd: use check_add_overflow() to prevent u16 DACL size overflow

set_posix_acl_entries_dacl() and set_ntacl_dacl() accumulate ACE sizes
in u16 variables. When a file has many POSIX ACL entries, the
accumulated size can wrap past 65535, causing the pointer arithmetic
(char *)pndace + *size to land within already-written ACEs. Subsequent
writes then overwrite earlier entries, and pndacl->size gets a
truncated value.

Use check_add_overflow() at each accumulation point to detect the
wrap before it corrupts the buffer, consistent with existing
check_mul_overflow() usage elsewhere in smbacl.c.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-31704");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
        {"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

21 Oct 2026 00:00Current
5.8Medium risk
Vulners AI Score5.8
CVSS 3.15.5
EPSS0.00162
3