Siemens SIMATIC S7-1500 TM MFP Improper Validation of Consistency within Input (CVE-2026-31488)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(506305);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/21");
script_cve_id("CVE-2026-31488");
script_name(english:"Siemens SIMATIC S7-1500 TM MFP Improper Validation of Consistency within Input (CVE-2026-31488)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
drm/amd/display: Do not skip unrelated mode changes in DSC validation
Starting with commit 17ce8a6907f7 ('drm/amd/display: Add dsc pre-validation in
atomic check'), amdgpu resets the CRTC state mode_changed flag to false when
recomputing the DSC configuration results in no timing change for a particular
stream.
However, this is incorrect in scenarios where a change in MST/DSC configuration
happens in the same KMS commit as another (unrelated) mode change. For example,
the integrated panel of a laptop may be configured differently (e.g., HDR
enabled/disabled) depending on whether external screens are attached. In this
case, plugging in external DP-MST screens may result in the mode_changed flag
being dropped incorrectly for the integrated panel if its DSC configuration
did not change during precomputation in pre_validate_dsc().
At this point, however, dm_update_crtc_state() has already created new streams
for CRTCs with DSC-independent mode changes. In turn,
amdgpu_dm_commit_streams() will never release the old stream, resulting in a
memory leak. amdgpu_dm_atomic_commit_tail() will never acquire a reference to
the new stream either, which manifests as a use-after-free when the stream gets
disabled later on:
BUG: KASAN: use-after-free in dc_stream_release+0x25/0x90 [amdgpu]
Write of size 4 at addr ffff88813d836524 by task kworker/9:9/29977
Workqueue: events drm_mode_rmfb_work_fn
Call Trace:
<TASK>
dump_stack_lvl+0x6e/0xa0
print_address_description.constprop.0+0x88/0x320
? dc_stream_release+0x25/0x90 [amdgpu]
print_report+0xfc/0x1ff
? srso_alias_return_thunk+0x5/0xfbef5
? __virt_addr_valid+0x225/0x4e0
? dc_stream_release+0x25/0x90 [amdgpu]
kasan_report+0xe1/0x180
? dc_stream_release+0x25/0x90 [amdgpu]
kasan_check_range+0x125/0x200
dc_stream_release+0x25/0x90 [amdgpu]
dc_state_destruct+0x14d/0x5c0 [amdgpu]
dc_state_release.part.0+0x4e/0x130 [amdgpu]
dm_atomic_destroy_state+0x3f/0x70 [amdgpu]
drm_atomic_state_default_clear+0x8ee/0xf30
? drm_mode_object_put.part.0+0xb1/0x130
__drm_atomic_state_free+0x15c/0x2d0
atomic_remove_fb+0x67e/0x980
Since there is no reliable way of figuring out whether a CRTC has unrelated
mode changes pending at the time of DSC validation, remember the value of the
mode_changed flag from before the point where a CRTC was marked as potentially
affected by a change in DSC configuration. Reset the mode_changed flag to this
earlier value instead in pre_validate_dsc().
(cherry picked from commit cc7c7121ae082b7b82891baa7280f1ff2608f22b)
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-31488");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(1288);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
21 Oct 2026 00:00Current
6.8Medium risk
Vulners AI Score6.8
CVSS 3.17.8
EPSS0.0019
SSVC