| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| CVE-2025-40757 | 11 Sep 202510:00 | – | circl | |
| Siemens APOGEE PXC Series和Siemens TALON TC Series 信息泄露漏洞 | 9 Sep 202500:00 | – | cnnvd | |
| CVE-2025-40757 | 9 Sep 202508:47 | – | cve | |
| CVE-2025-40757 | 9 Sep 202508:47 | – | cvelist | |
| EUVD-2025-27241 | 3 Oct 202520:07 | – | euvd | |
| Siemens Apogee PXC and Talon TC Devices | 9 Sep 202500:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 9 Sep 202511:06 | – | ncsc | |
| CVE-2025-40757 | 9 Sep 202509:15 | – | nvd | |
| PT-2025-36680 | 9 Sep 202500:00 | – | ptsecurity | |
| CVE-2025-40757 | 11 Sep 202509:20 | – | redhatcve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503573);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");
script_cve_id("CVE-2025-40757");
script_xref(name:"ICSA", value:"25-254-05");
script_name(english:"Siemens Apogee PXC and Talon TC Devices Exposure of Sensitive Information to an Unauthorized Actor (CVE-2025-40757)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Affected devices connected to the network allow unrestricted access to
sensitive files, such as databases. This could allow an attacker to
download encrypted .db file containing passwords.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-916339.html");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-254-05");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- Ensure all three default passwords are changed, even if not in use.
- Ensure that passwords for all accounts are strong and hard to guess. Passwords can be 15 characters long and can
contain upper case, lower case, numbers and special characters.
- Disable telnet (telnet is disabled by default).
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-916339 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40757");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(200);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/09/09");
script_set_attribute(attribute:"patch_publication_date", value:"2025/09/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:apogee_pxc_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:apogee_pxc_firmware" :
{"family" : "Apogee"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation