Siemens SCALANCE LPE9403 Cleartext Transmission of Sensitive Information (CVE-2025-40583)

🗓️ 24 Jul 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

Siemens SCALANCE LPE9403 transmits sensitive information in cleartext, exposing it to local attackers.

Related
Refs
Code
ReporterTitlePublishedViews
Family
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software lies in the improper limitation of the path name in the restricted access catalog, which allows attackers to restore backup copies within the system.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software lies in the improper assignment of permissions for critical resources, allowing attackers to enhance their privileges and gain unauthorized access to protected information.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of the SINEMA Remote Connect Edge Client microprogramming software for industrial switches from Siemens, model Siemens Scalance LPE9403, allows a perpetrator to bypass authentication procedures and gain access to read and modify configuration parameters.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of the SINEMA Remote Connect Edge Client microprogramming software for industrial switches from Siemens, model Scalance LPE9403, allows a perpetrator to execute arbitrary commands.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software lies in errors during the assignment of permissions to critical resources, allowing attackers to gain unauthorized access to protected information.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of the dcpd service in the microprogramming software of Siemens Scalance LPE9403 allows a hacker to trigger a maintenance failure.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of the dcpd service in the microprogramming software of Siemens Scalance LPE9403 allows a hacker to trigger a maintenance failure.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software is related to buffer overflow in the stack. This allows a hacker to trigger a service failure or execute arbitrary code.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software, related to the transmission of secret information in the form of open text, allows a intruder to gain unauthorized access to the protected information.
28 May 202500:00
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software is related to buffer overflow in the stack. This allows a hacker to trigger a service failure or execute arbitrary code.
28 May 202500:00
bdu_fstec
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503293);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");

  script_cve_id("CVE-2025-40583");
  script_xref(name:"ICSA", value:"25-135-18");

  script_name(english:"Siemens SCALANCE LPE9403 Cleartext Transmission of Sensitive Information (CVE-2025-40583)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in SCALANCE LPE9403
(6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge
Client installed). Affected devices do transmit sensitive information
in cleartext. This could allow a privileged local attacker to retrieve
this sensitive information.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-327438.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-18");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SCALANCE LPE9403 (6GK5998-3GS00-2AC2): Currently no fix is available
- SCALANCE LPE9403 (6GK5998-3GS00-2AC2)(CVE-2025-40572, CVE-2025-40573, CVE-2025-40574, CVE-2025-40579, CVE-2025-40580,
CVE-2025-40581, CVE-2025-40582, CVE-2025-40583): Restrict access to authorized and trusted personal only
- SCALANCE LPE9403 (6GK5998-3GS00-2AC2)(CVE-2025-40575, CVE-2025-40576, CVE-2025-40577, CVE-2025-40578): Disable the
Profinet Discovery and Configuration Protocol (DCP) service
- SCALANCE LPE9403 (6GK5998-3GS00-2AC2)(CVE-2025-40582): Only use trusted SINEMA Remote Connect Servers

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-327438 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40583");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(319);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/05/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/05/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/07/24");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9403_firmware:-");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_lpe9403_firmware:-" :
        {"family" : "SCALANCE", "orderNumbers" : ["6GK5998-3GS00-2AC2"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

01 Apr 2026 00:00Current
5.7Medium risk
Vulners AI Score5.7
CVSS 3.17.8
CVSS 48.5
EPSS0.00392
SSVC
2