| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| The vulnerability of the “Load Configuration from Local PC” component of the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM RST2428P, SCALANCE XC-300 Series, SCALANCE XC-400 Series, SCALANCE XCM-/XRM-/XCH-/XRH-300 Series, SCALANCE XM-400/XR-500 Series, SCALANCE XR-300 (6GK5334-xTSxx) Series, allows a attacker to compromise the integrity of protected information. | 29 Aug 202500:00 | – | bdu_fstec | |
| CVE-2025-40569 | 10 Jun 202515:30 | – | circl | |
| Siemens多款产品 竞争条件问题漏洞 | 10 Jun 202500:00 | – | cnnvd | |
| CVE-2025-40569 | 10 Jun 202515:17 | – | cve | |
| CVE-2025-40569 | 10 Jun 202515:17 | – | cvelist | |
| EUVD-2025-17679 | 3 Oct 202520:07 | – | euvd | |
| Vulnerabilities fixed in Siemens products | 10 Jun 202513:11 | – | ncsc | |
| CVE-2025-40569 | 10 Jun 202516:15 | – | nvd | |
| PT-2025-24677 · Siemens · Scalance Xr326-8 Eec +20 | 10 Jun 202500:00 | – | ptsecurity | |
| CVE-2025-40569 | 9 Jan 202609:16 | – | redhatcve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505103);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");
script_cve_id("CVE-2025-40569");
script_xref(name:"ICSA", value:"25-162-04");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Concurrent Execution Using Shared Resource with Improper Synchronization (CVE-2025-40569)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The Load Configuration from Local PC functionality in the web
interface of affected products contains a race condition
vulnerability. This could allow an authenticated remote attacker to
make the affected product load an attacker controlled configuration
instead of the legitimate one. Successful exploitation requires that a
legitimate administrator invokes the functionality and the attacker
wins the race condition.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-693776.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-04");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- RUGGEDCOM RST2428P (6GK6242-6PA00), SCALANCE XC316-8 (6GK5324-8TS00-2AC2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2),
SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2), SCALANCE XC332 (6GK5332-0GA00-2AC2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2),
SCALANCE XC424-4 (6GK5428-4TR00-2AC2), SCALANCE XC432 (6GK5432-0GR00-2AC2), SCALANCE XCH328 (6GK5328-4TS01-2EC2),
SCALANCE XCM324 (6GK5324-8TS01-2AC2), SCALANCE XCM328 (6GK5328-4TS01-2AC2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3),
SCALANCE XR302-32 (6GK5334-5TS00-3AR3), SCALANCE XR302-32 (6GK5334-5TS00-4AR3), SCALANCE XR322-12 (6GK5334-3TS00-2AR3),
SCALANCE XR322-12 (6GK5334-3TS00-3AR3), SCALANCE XR322-12 (6GK5334-3TS00-4AR3), SCALANCE XR326-8 (6GK5334-2TS00-2AR3),
SCALANCE XR326-8 (6GK5334-2TS00-3AR3), SCALANCE XR326-8 (6GK5334-2TS00-4AR3), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3),
SCALANCE XR502-32 (6GK5534-5TR00-2AR3), SCALANCE XR502-32 (6GK5534-5TR00-3AR3), SCALANCE XR502-32 (6GK5534-5TR00-4AR3),
SCALANCE XR522-12 (6GK5534-3TR00-2AR3), SCALANCE XR522-12 (6GK5534-3TR00-3AR3), SCALANCE XR522-12 (6GK5534-3TR00-4AR3),
SCALANCE XR526-8 (6GK5534-2TR00-2AR3), SCALANCE XR526-8 (6GK5534-2TR00-3AR3), SCALANCE XR526-8 (6GK5534-2TR00-4AR3),
SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3),
SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)
(6GK5334-5TS01-4AR3), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3), SCALANCE XRM334 (24 V DC, 12xFO)
(6GK5334-3TS01-2AR3), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3), SCALANCE XRM334 (230 V AC,
8xFO) (6GK5334-2TS01-3AR3), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3), SCALANCE XRM334 (230V AC, 2x10G,
24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3): Update to V3.2 or later version
- SCALANCE XCM332 (6GK5332-0GA01-2AC2): Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-693776 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N");
script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-40569");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(362);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/06/10");
script_set_attribute(attribute:"patch_publication_date", value:"2025/06/10");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xch328_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
"cpe:/o:siemens:scalance_xcm324_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
"cpe:/o:siemens:scalance_xcm328_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
"cpe:/o:siemens:scalance_xcm332_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation