Lucene search
+L

Siemens SCALANCE and RUGGEDCOM Improper Input Validation (CVE-2025-39860)

🗓️ 10 Feb 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 11 Views

Linux kernel Bluetooth use-after-free in l2cap_sock_cleanup_listen fixed; race could touch freed socket CVE-2025-39860.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(505138);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2025-39860");
  script_xref(name:"ICSA", value:"26-043-06");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Improper Input Validation (CVE-2025-39860)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
Bluetooth: Fix use-after-free in l2cap_sock_cleanup_listen()  syzbot
reported the splat below without a repro.  In the splat, a single
thread calling bt_accept_dequeue() freed sk and touched it after that.
The root cause would be the racy l2cap_sock_cleanup_listen() call
added by the cited commit.  bt_accept_dequeue() is called under
lock_sock() except for l2cap_sock_release().  Two threads could see
the same socket during the list iteration in bt_accept_dequeue():
CPU1                        CPU2 (close())   ----
----   sock_hold(sk)               sock_hold(sk);   lock_sock(sk)
<-- block close()   sock_put(sk)   bt_accept_unlink(sk)
sock_put(sk)  <-- refcnt by bt_accept_enqueue()   release_sock(sk)
lock_sock(sk)                               sock_put(sk)
bt_accept_unlink(sk)                                 sock_put(sk)
<-- last refcnt                               bt_accept_unlink(sk)
<-- UAF  Depending on the timing, the other thread could show up in
the Freed by task part.  Let's call l2cap_sock_cleanup_listen()
under lock_sock() in l2cap_sock_release().  [0]: BUG: KASAN: slab-use-
after-free in debug_spin_lock_before
kernel/locking/spinlock_debug.c:86 [inline] BUG: KASAN: slab-use-
after-free in do_raw_spin_lock+0x26f/0x2b0
kernel/locking/spinlock_debug.c:115 Read of size 4 at addr
ffff88803b7eb1c4 by task syz.5.3276/16995 CPU: 3 UID: 0 PID: 16995
Comm: syz.5.3276 Not tainted syzkaller #0 PREEMPT(full) Hardware name:
QEMU Standard PC (Q35 + ICH9, 2009), BIOS
1.16.3-debian-1.16.3-2~bpo12+1 04/01/2014 Call Trace:  <TASK>
__dump_stack lib/dump_stack.c:94 [inline]  dump_stack_lvl+0x116/0x1f0
lib/dump_stack.c:120  print_address_description mm/kasan/report.c:378
[inline]  print_report+0xcd/0x630 mm/kasan/report.c:482
kasan_report+0xe0/0x110 mm/kasan/report.c:595  debug_spin_lock_before
kernel/locking/spinlock_debug.c:86 [inline]
do_raw_spin_lock+0x26f/0x2b0 kernel/locking/spinlock_debug.c:115
spin_lock_bh include/linux/spinlock.h:356 [inline]
release_sock+0x21/0x220 net/core/sock.c:3746
bt_accept_dequeue+0x505/0x600 net/bluetooth/af_bluetooth.c:312
l2cap_sock_cleanup_listen+0x5c/0x2a0 net/bluetooth/l2cap_sock.c:1451
l2cap_sock_release+0x5c/0x210 net/bluetooth/l2cap_sock.c:1425
__sock_release+0xb3/0x270 net/socket.c:649  sock_close+0x1c/0x30
net/socket.c:1439  __fput+0x3ff/0xb70 fs/file_table.c:468
task_work_run+0x14d/0x240 kernel/task_work.c:227
resume_user_mode_work include/linux/resume_user_mode.h:50 [inline]
exit_to_user_mode_loop+0xeb/0x110 kernel/entry/common.c:43
exit_to_user_mode_prepare include/linux/irq-entry-common.h:225
[inline]  syscall_exit_to_user_mode_work include/linux/entry-
common.h:175 [inline]  syscall_exit_to_user_mode include/linux/entry-
common.h:210 [inline]  do_syscall_64+0x3f6/0x4c0
arch/x86/entry/syscall_64.c:100
entry_SYSCALL_64_after_hwframe+0x77/0x7f RIP: 0033:0x7f2accf8ebe9
Code: ff ff c3 66 2e 0f 1f 84 00 00 00 00 00 0f 1f 40 00 48 89 f8 48
89 f7 48 89 d6 48 89 ca 4d 89 c2 4d 89 c8 4c 8b 4c 24 08 0f 05 <48> 3d
01 f0 ff ff 73 01 c3 48 c7 c1 a8 ff ff ff f7 d8 64 89 01 48 RSP:
002b:00007ffdb6cb1378 EFLAGS: 00000246 ORIG_RAX: 00000000000001b4 RAX:
0000000000000000 RBX: 00000000000426fb RCX: 00007f2accf8ebe9 RDX:
0000000000000000 RSI: 000000000000001e RDI: 0000000000000003 RBP:
00007f2acd1b7da0 R08: 0000000000000001 R09: 00000012b6cb166f R10:
0000001b30e20000 R11: 0000000000000246 R12: 00007f2acd1b609c R13:
00007f2acd1b6090 R14: ffffffffffffffff R15: 00007ffdb6cb1490  </TASK>
Allocated by task 5326:  kasan_save_stack+0x33/0x60
mm/kasan/common.c:47  kasan_save_track+0x14/0x30 mm/kasan/common.c:68
poison_kmalloc_redzone mm/kasan/common.c:388 [inline]
__kasan_kmalloc+0xaa/0xb0 mm/kasan/common.c:405  kasan_kmalloc
include/linux/kasan.h:260 [inline]  __do_kmalloc_node mm/slub.c:4365
[inline]  __kmalloc_nopro ---truncated---

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997626/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-39860");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/09/19");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/01/28");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xch328_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
    "cpe:/o:siemens:scalance_xcm324_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
    "cpe:/o:siemens:scalance_xcm328_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
    "cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
    "cpe:/o:siemens:scalance_xcm332_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
6.3Medium risk
Vulners AI Score6.3
CVSS 3.17.8 - 8
EPSS0.00226
11