| Reporter | Title | Published | Views | Family All 185 |
|---|---|---|---|---|
| Astra Linux – Vulnerability found in Linux 6.1, Linux 6.12 | 1 Nov 202510:54 | – | astralinux | |
| The vulnerability in the driver net/usb/asix_devices.c of the Linux operating system allows a hacker to cause a service failure. | 15 Dec 202500:00 | – | bdu_fstec | |
| CVE-2025-38725 affecting package kernel for versions less than 6.6.104.2-1 | 1 Oct 202519:21 | – | cbl_mariner | |
| CVE-2025-38725 affecting package kernel for versions less than 5.15.200.1-1 | 9 Mar 202614:32 | – | cbl_mariner | |
| CVE-2025-38725 | 4 Sep 202519:39 | – | circl | |
| Linux kernel 安全漏洞 | 4 Sep 202500:00 | – | cnnvd | |
| CVE-2025-38725 | 4 Sep 202515:33 | – | cve | |
| CVE-2025-38725 net: usb: asix_devices: add phy_mask for ax88772 mdio bus | 4 Sep 202515:33 | – | cvelist | |
| [SECURITY] [DLA 4328-1] linux-6.1 security update | 13 Oct 202509:16 | – | debian | |
| [SECURITY] [DSA 6009-1] linux security update | 22 Sep 202521:10 | – | debian |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505702);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/28");
script_cve_id("CVE-2025-38725");
script_name(english:"Siemens SIMATIC S7-1500 CPU 1518 MFP Improper Input Validation (CVE-2025-38725)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
net: usb: asix_devices: add phy_mask for ax88772 mdio bus Without
setting phy_mask for ax88772 mdio bus, current driver may create at
most 32 mdio phy devices with phy address range from 0x00 ~ 0x1f.
DLink DUB-E100 H/W Ver B1 is such a device. However, only one main phy
device will bind to net phy driver. This is creating issue during
system suspend/resume since phy_polling_mode() in phy_state_machine()
will directly deference member of phydev->drv for non-main phy
devices. Then NULL pointer dereference issue will occur. Due to only
external phy or internal phy is necessary, add phy_mask for ax88772
mdio bus to workarnoud the issue.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-019113.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-032379.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814144/");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-38725");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/09/04");
script_set_attribute(attribute:"patch_publication_date", value:"2026/05/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.6");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.6" :
{"versionStartIncluding" : "3.1.6", "family" : "S71500", "orderNumbers" : ['6ES7518-4FX00-1AB0', '6ES7518-4AX00-1AC0', '6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware" :
{"family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation