Siemens SCALANCE and RUGGEDCOM Improper Input Validation (CVE-2025-38086)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505134);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");
script_cve_id("CVE-2025-38086");
script_xref(name:"ICSA", value:"26-043-06");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Improper Input Validation (CVE-2025-38086)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
net: ch9200: fix uninitialised access during mii_nway_restart In
mii_nway_restart() the code attempts to call mii->mdio_read which is
ch9200_mdio_read(). ch9200_mdio_read() utilises a local buffer called
buff, which is initialised with control_read(). However buff is
conditionally initialised inside control_read(): if (err ==
size) { memcpy(data, buf, size); } If the
condition of err == size is not met, then buff remains
uninitialised. Once this happens the uninitialised buff is accessed
and returned during ch9200_mdio_read(): return (buff[0] |
buff[1] << 8); The problem stems from the fact that
ch9200_mdio_read() ignores the return value of control_read(), leading
to uinit-access of buff. To fix this we should check the return
value of control_read() and return early on error.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997626/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-38086");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/06/28");
script_set_attribute(attribute:"patch_publication_date", value:"2026/01/28");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xch328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
"cpe:/o:siemens:scalance_xcm324_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
"cpe:/o:siemens:scalance_xcm328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
"cpe:/o:siemens:scalance_xcm332_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
05 Mar 2026 00:00Current
6.5Medium risk
Vulners AI Score6.5
CVSS 3.15.5