| Reporter | Title | Published | Views | Family All 37 |
|---|---|---|---|---|
| CVE-2025-27587 | 16 Jun 202522:40 | – | circl | |
| OpenSSL 安全漏洞 | 16 Jun 202500:00 | – | cnnvd | |
| CVE-2025-27587 | 16 Jun 202500:00 | – | cve | |
| CVE-2025-27587 | 16 Jun 202500:00 | – | cvelist | |
| CVE-2025-27587 | 16 Jun 202500:00 | – | debiancve | |
| EUVD-2025-18430 | 3 Oct 202520:07 | – | euvd | |
| K000156613: OpenSSL for PowerPC vulnerability CVE-2025-27587 | 24 Sep 202516:19 | – | f5 | |
| Vulnerabilities fixed in Oracle Communications products | 23 Oct 202513:20 | – | ncsc | |
| CVE-2025-27587 | 16 Jun 202522:15 | – | nvd | |
| libopenssl-3-devel-3.5.0-3.1 on GA media (moderate) | 31 May 202500:00 | – | opensuse |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505127);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");
script_cve_id("CVE-2025-27587");
script_xref(name:"ICSA", value:"26-043-06");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Covert Timing Channel (CVE-2025-27587)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"OpenSSL 3.0.0 through 3.3.2 on the PowerPC architecture is vulnerable
to a Minerva attack, exploitable by measuring the time of signing of
random messages using the EVP_DigestSign API, and then using the
private key to extract the K value (nonce) from the signatures. Next,
based on the bit size of the extracted nonce, one can compare the
signing time of full-sized nonces to signatures that used smaller
nonces, via statistical tests. There is a side-channel in the P-364
curve that allows private key extraction (also, there is a dependency
between the bit size of K and the size of the side channel). NOTE:
This CVE is disputed because the OpenSSL security policy explicitly
notes that any side channels which require same physical system to be
detected are outside of the threat model for the software. The timing
signal is so small that it is infeasible to be detected without having
the attacking process running on the same physical system.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997626/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-27587");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(385);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/05/22");
script_set_attribute(attribute:"patch_publication_date", value:"2026/01/28");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xch328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
"cpe:/o:siemens:scalance_xcm324_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
"cpe:/o:siemens:scalance_xcm328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
"cpe:/o:siemens:scalance_xcm332_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation