Siemens SIMATIC Devices Improper Input Validation (CVE-2025-21756)
| Reporter | Title | Published | Views | Family All 577 |
|---|---|---|---|---|
| exploit-lab | 27 May 202620:55 | – | githubexploit | |
| Exploit for Improper Validation of Array Index in Linux Linux_Kernel | 13 Sep 202517:12 | – | githubexploit | |
| Exploit for Use After Free in Linux Linux_Kernel | 18 Apr 202514:22 | – | githubexploit | |
| Amazon Linux 2023 : bpftool, kernel, kernel-devel (ALAS2023-2025-915) | 1 Apr 202500:00 | – | nessus | |
| Amazon Linux 2 : kernel, --advisory ALAS2KERNEL-5.10-2025-088 (ALASKERNEL-5.10-2025-088) | 17 Apr 202500:00 | – | nessus | |
| Amazon Linux 2 : kernel, --advisory ALAS2KERNEL-5.15-2025-069 (ALASKERNEL-5.15-2025-069) | 1 Apr 202500:00 | – | nessus | |
| AlmaLinux 9 : kernel (ALSA-2025:7903) | 26 May 202500:00 | – | nessus | |
| AlmaLinux 8 : kernel (ALSA-2025:8056) | 21 May 202500:00 | – | nessus | |
| AlmaLinux 8 : kernel-rt (ALSA-2025:8057) | 21 May 202500:00 | – | nessus | |
| Azure Linux 3.0 Security Update: kernel (CVE-2025-21756) | 6 May 202500:00 | – | nessus |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503431);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");
script_cve_id("CVE-2025-21756");
script_xref(name:"ICSA", value:"25-162-05");
script_name(english:"Siemens SIMATIC Devices Improper Input Validation (CVE-2025-21756)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"vsock: Keep the binding until socket destruction Preserve sockets
bindings; this includes both resulting from an explicit bind() and
those implicitly bound through autobind during connect().
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-082556.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-265688.html");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-05");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens is preparing fixed versions and reports that currently, no fix is available.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-082556 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:H/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-21756");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_set_attribute(attribute:"exploited_by_malware", value:"true");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"patch_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1", "versionStartIncluding" : "1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]},
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
{"versionStartIncluding" : "3.1.5", "family" : "S71500", "orderNumbers" : ['6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AB0', '6ES7518-4AX00-1AC0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware" :
{"versionStartIncluding" : "3.1.5", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
14 Feb 2026 00:00Current
7.3High risk
Vulners AI Score7.3
CVSS 3.17.8
EPSS0.00873
SSVC