#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505542);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/13");
script_cve_id("CVE-2025-15467");
script_name(english:"Siemens SCALANCE, RUGGEDCOM, and SIPLUS Out-of-bounds Write (CVE-2025-15467)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Issue summary: Parsing CMS AuthEnvelopedData message with maliciously
crafted AEAD parameters can trigger a stack buffer overflow. Impact
summary: A stack buffer overflow may lead to a crash, causing Denial
of Service, or potentially remote code execution. When parsing CMS
AuthEnvelopedData structures that use AEAD ciphers such as AES-GCM,
the IV (Initialization Vector) encoded in the ASN.1 parameters is
copied into a fixed-size stack buffer without verifying that its
length fits the destination. An attacker can supply a crafted CMS
message with an oversized IV, causing a stack-based out-of-bounds
write before any authentication or tag verification occurs.
Applications and services that parse untrusted CMS or PKCS#7 content
using AEAD ciphers (e.g., S/MIME AuthEnvelopedData with AES-GCM) are
vulnerable. Because the overflow occurs prior to authentication, no
valid key material is required to trigger it. While exploitability to
remote code execution depends on platform and toolchain mitigations,
the stack-based write primitive represents a severe risk. The FIPS
modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue,
as the CMS implementation is outside the OpenSSL FIPS module
boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this
issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-434797.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109825750/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109996963/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/110000985/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109999722/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/110000657/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/110000400/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109991080/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/110000730/");
# https://docs.eu1.edge.siemens.cloud/release_notes/scope_of_delivery/scope_of_delivery.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?024e11ca");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109800912/");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-15467");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(787);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/06/09");
script_set_attribute(attribute:"patch_publication_date", value:"2026/06/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_eu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_nam_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9403_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9413_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9433_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m804pb_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m812-1_adsl-router_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m816-1_adsl-router_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m826-2_shdsl-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-3_3g-router_%28cn%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-3_%28rok%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_%28nam%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mub852-1_%28a1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mub852-1_%28b1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28a1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28b1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28a1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28b1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28cn%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28row%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_s615_eec_lan-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_s615_lan-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc622-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc626-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc632-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc636-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc642-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_sc646-2c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wab762-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_%28me%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_%28us%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28me%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28me%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wub762-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wub762-1_ifeatures_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum763-1_%28us%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum763-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28me%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28usa%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x200-4p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x201-3p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x201-3p_irt_pro_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2p_irt_pro_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2fm_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ld_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ld_ts_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ts_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204irt_pro_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x206-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x206-1ld_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x208_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x208pro_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x212-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x212-2ld_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x216_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x224_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%28230v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%28230v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%2824v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%2824v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x304-2fe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x306-1ld_fe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%28230v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%28230v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%2824v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%2824v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%2c_coated%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-3ld_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2ld_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2lh%2b_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2lh_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_poe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_ts_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x310_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x310fe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x320-1-2ld_fe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x320-1_fe_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x408-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc316-8_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc324-4_eec_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc324-4_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc332_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc416-8_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc424-4_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc432_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf201-3p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf202-2p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204-2ba_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf206-1_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf208_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr302-32_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr322-12_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_ts_%2824v%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_rear%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_ts_%2824v%2c_ports_on_front%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr326-8_eec_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr326-8_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr502-32_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr522-12_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr524-8wg_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr526-8_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_scalance_x202-2p_irt_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_scalance_x308-2_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:scalance_lpe9413_firmware" :
{"family" : "SCALANCE", "orderNumbers" : ['6GK5998-3GS01-2AC2']},
"cpe:/o:siemens:scalance_lpe9433_firmware" :
{"family" : "SCALANCE", "orderNumbers" : ['6GK5998-3GS11-2AC2']},
"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_eu_firmware" :
{"family" : "RuggedCom", "orderNumbers" : ['6GK6108-4AM00-2BA2']},
"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_nam_firmware" :
{"family" : "RuggedCom", "orderNumbers" : ['6GK6108-4AM00-2DA2']},
"cpe:/o:siemens:scalance_lpe9403_firmware" :
{"family" : "SCALANCE", "orderNumbers" : ['6GK5998-3GS00-2AC2']},
"cpe:/o:siemens:scalance_m804pb_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5804-0AP00-2AA2']},
"cpe:/o:siemens:scalance_m812-1_adsl-router_series_firmware" :
{"family" : "SCALANCEM"},
"cpe:/o:siemens:scalance_m816-1_adsl-router_series_firmware" :
{"family" : "SCALANCEM"},
"cpe:/o:siemens:scalance_m826-2_shdsl-router_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5826-2AB00-2AB2']},
"cpe:/o:siemens:scalance_m874-2_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5874-2AA00-2AA2']},
"cpe:/o:siemens:scalance_m874-3_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5874-3AA00-2AA2']},
"cpe:/o:siemens:scalance_m874-3_3g-router_%28cn%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5874-3AA00-2FA2']},
"cpe:/o:siemens:scalance_m876-3_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5876-3AA02-2BA2']},
"cpe:/o:siemens:scalance_m876-3_%28rok%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5876-3AA02-2EA2']},
"cpe:/o:siemens:scalance_m876-4_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA10-2BA2']},
"cpe:/o:siemens:scalance_m876-4_%28eu%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA00-2BA2']},
"cpe:/o:siemens:scalance_m876-4_%28nam%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA00-2DA2']},
"cpe:/o:siemens:scalance_mub852-1_%28a1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5852-1EA10-1AA1']},
"cpe:/o:siemens:scalance_mub852-1_%28b1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5852-1EA10-1BA1']},
"cpe:/o:siemens:scalance_mum853-1_%28a1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA10-2AA1']},
"cpe:/o:siemens:scalance_mum853-1_%28b1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA10-2BA1']},
"cpe:/o:siemens:scalance_mum853-1_%28eu%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA00-2DA1']},
"cpe:/o:siemens:scalance_mum856-1_%28a1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA10-3AA1']},
"cpe:/o:siemens:scalance_mum856-1_%28b1%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA10-3BA1']},
"cpe:/o:siemens:scalance_mum856-1_%28cn%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3FA1']},
"cpe:/o:siemens:scalance_mum856-1_%28eu%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3DA1']},
"cpe:/o:siemens:scalance_mum856-1_%28row%29_firmware" :
{"family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3AA1']},
"cpe:/o:siemens:scalance_s615_eec_lan-router_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5615-0AA01-2AA2']},
"cpe:/o:siemens:scalance_s615_lan-router_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5615-0AA00-2AA2']},
"cpe:/o:siemens:scalance_sc622-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5622-2GS00-2AC2']},
"cpe:/o:siemens:scalance_sc626-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5626-2GS00-2AC2']},
"cpe:/o:siemens:scalance_sc632-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5632-2GS00-2AC2']},
"cpe:/o:siemens:scalance_sc636-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5636-2GS00-2AC2']},
"cpe:/o:siemens:scalance_sc642-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5642-2GS00-2AC2']},
"cpe:/o:siemens:scalance_sc646-2c_firmware" :
{"family" : "SCALANCES", "orderNumbers" : ['6GK5646-2GS00-2AC2']},
"cpe:/o:siemens:scalance_wab762-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-6AA0']},
"cpe:/o:siemens:scalance_wam763-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DA0']},
"cpe:/o:siemens:scalance_wam763-1_%28me%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DC0']},
"cpe:/o:siemens:scalance_wam763-1_%28us%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DB0']},
"cpe:/o:siemens:scalance_wam766-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DA0']},
"cpe:/o:siemens:scalance_wam766-1_%28me%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DC0']},
"cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DB0']},
"cpe:/o:siemens:scalance_wam766-1_eec_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TA0']},
"cpe:/o:siemens:scalance_wam766-1_eec_%28me%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TC0']},
"cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TB0']},
"cpe:/o:siemens:scalance_wub762-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-1AA0']},
"cpe:/o:siemens:scalance_wub762-1_ifeatures_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-2AA0']},
"cpe:/o:siemens:scalance_wum763-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-3AA0', '6GK5763-1AL00-3DA0']},
"cpe:/o:siemens:scalance_wum763-1_%28us%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-3AB0', '6GK5763-1AL00-3DB0']},
"cpe:/o:siemens:scalance_wum766-1_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DA0']},
"cpe:/o:siemens:scalance_wum766-1_%28me%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DC0']},
"cpe:/o:siemens:scalance_wum766-1_%28usa%29_firmware" :
{"family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DB0']},
"cpe:/o:siemens:scalance_x200-4p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5200-4AH10-2BA3', '6GK5200-4AH00-2BA3']},
"cpe:/o:siemens:scalance_x201-3p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3BH00-2BA3', '6GK5201-3BH10-2BA3']},
"cpe:/o:siemens:scalance_x201-3p_irt_pro_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3JR00-2BA6', '6GK5201-3JR10-2BA6']},
"cpe:/o:siemens:scalance_x202-2irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BB10-2BA3', '6GK5202-2BB00-2BA3']},
"cpe:/o:siemens:scalance_x202-2p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BH00-2BA3', '6GK5202-2BH10-2BA3']},
"cpe:/o:siemens:scalance_x202-2p_irt_pro_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2JR00-2BA6', '6GK5202-2JR10-2BA6']},
"cpe:/o:siemens:scalance_x204-2_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB10-2AA3']},
"cpe:/o:siemens:scalance_x204-2fm_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB11-2AA3']},
"cpe:/o:siemens:scalance_x204-2ld_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BC10-2AA3']},
"cpe:/o:siemens:scalance_x204-2ld_ts_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BC10-2CA2']},
"cpe:/o:siemens:scalance_x204-2ts_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB10-2CA2']},
"cpe:/o:siemens:scalance_x204irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0BA00-2BA3', '6GK5204-0BA10-2BA3']},
"cpe:/o:siemens:scalance_x204irt_pro_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0JA10-2BA6', '6GK5204-0JA00-2BA6']},
"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']},
"cpe:/o:siemens:scalance_x206-1_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BB10-2AA3']},
"cpe:/o:siemens:scalance_x206-1ld_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BC10-2AA3']},
"cpe:/o:siemens:scalance_x208_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5208-0BA10-2AA3']},
"cpe:/o:siemens:scalance_x208pro_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5208-0HA10-2AA6']},
"cpe:/o:siemens:scalance_x212-2_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5212-2BB00-2AA3']},
"cpe:/o:siemens:scalance_x212-2ld_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5212-2BC00-2AA3']},
"cpe:/o:siemens:scalance_x216_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5216-0BA00-2AA3']},
"cpe:/o:siemens:scalance_x224_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5224-0BA00-2AA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%28230v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-3GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%28230v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-3EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%2824v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-1GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%2824v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-1EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-4GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-4EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-2GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-2EA3']},
"cpe:/o:siemens:scalance_x304-2fe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5304-2BD00-2AA3']},
"cpe:/o:siemens:scalance_x306-1ld_fe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5306-1BF00-2AA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%28230v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-3GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%28230v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-3EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%2824v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-1GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%2824v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-1EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-4GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-4EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%2c_coated%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-2GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-2EA3']},
"cpe:/o:siemens:scalance_x307-3_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-3BL10-2AA3', '6GK5307-3BL00-2AA3']},
"cpe:/o:siemens:scalance_x307-3ld_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-3BM00-2AA3', '6GK5307-3BM10-2AA3']},
"cpe:/o:siemens:scalance_x308-2_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FL00-2AA3', '6GK5308-2FL10-2AA3']},
"cpe:/o:siemens:scalance_x308-2ld_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FM10-2AA3', '6GK5308-2FM00-2AA3']},
"cpe:/o:siemens:scalance_x308-2lh_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FN10-2AA3', '6GK5308-2FN00-2AA3']},
"cpe:/o:siemens:scalance_x308-2lh%2b_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FP10-2AA3', '6GK5308-2FP00-2AA3']},
"cpe:/o:siemens:scalance_x308-2m_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2GG10-2AA2', '6GK5308-2GG00-2AA2']},
"cpe:/o:siemens:scalance_x308-2m_poe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2QG10-2AA2', '6GK5308-2QG00-2AA2']},
"cpe:/o:siemens:scalance_x308-2m_ts_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2GG10-2CA2', '6GK5308-2GG00-2CA2']},
"cpe:/o:siemens:scalance_x310_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5310-0FA00-2AA3', '6GK5310-0FA10-2AA3']},
"cpe:/o:siemens:scalance_x310fe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5310-0BA10-2AA3', '6GK5310-0BA00-2AA3']},
"cpe:/o:siemens:scalance_x320-1_fe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5320-1BD00-2AA3']},
"cpe:/o:siemens:scalance_x320-1-2ld_fe_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5320-3BF00-2AA3']},
"cpe:/o:siemens:scalance_x408-2_firmware" :
{"family" : "SCALANCEX400", "orderNumbers" : ['6GK5408-2FD00-2AA2']},
"cpe:/o:siemens:scalance_xc316-8_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS00-2AC2']},
"cpe:/o:siemens:scalance_xc324-4_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS00-2AC2']},
"cpe:/o:siemens:scalance_xc324-4_eec_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS00-2EC2']},
"cpe:/o:siemens:scalance_xc332_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA00-2AC2']},
"cpe:/o:siemens:scalance_xc416-8_firmware" :
{"family" : "SCALANCEX400", "orderNumbers" : ['6GK5424-8TR00-2AC2']},
"cpe:/o:siemens:scalance_xc424-4_firmware" :
{"family" : "SCALANCEX400", "orderNumbers" : ['6GK5428-4TR00-2AC2']},
"cpe:/o:siemens:scalance_xc432_firmware" :
{"family" : "SCALANCEX400", "orderNumbers" : ['6GK5432-0GR00-2AC2']},
"cpe:/o:siemens:scalance_xf201-3p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3BH00-2BD2']},
"cpe:/o:siemens:scalance_xf202-2p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BH00-2BD2']},
"cpe:/o:siemens:scalance_xf204_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2AF2']},
"cpe:/o:siemens:scalance_xf204-2_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BC00-2AF2']},
"cpe:/o:siemens:scalance_xf204-2ba_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-2AA00-2BD2']},
"cpe:/o:siemens:scalance_xf204irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0BA00-2BF2', '6GK5204-0BA10-2BF2']},
"cpe:/o:siemens:scalance_xf206-1_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BC00-2AF2']},
"cpe:/o:siemens:scalance_xf208_firmware" :
{"family" : "SCALANCEX200", "orderNumbers" : ['6GK5208-0BA00-2AF2']},
"cpe:/o:siemens:scalance_xr302-32_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS00-2AR3', '6GK5334-5TS00-3AR3', '6GK5334-5TS00-4AR3']},
"cpe:/o:siemens:scalance_xr322-12_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS00-2AR3', '6GK5334-3TS00-4AR3', '6GK5334-3TS00-3AR3']},
"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-3AR2', '6GK5324-0GG00-3AR2']},
"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG00-3HR2', '6GK5324-0GG10-3HR2']},
"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-1AR2', '6GK5324-0GG00-1AR2']},
"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-1HR2', '6GK5324-0GG00-1HR2']},
"cpe:/o:siemens:scalance_xr324-12m_ts_%2824v%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-1CR2', '6GK5324-0GG00-1CR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-3ER2', '6GK5324-4GG00-3ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-3JR2', '6GK5324-4GG00-3JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-1ER2', '6GK5324-4GG00-1ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG00-1JR2', '6GK5324-4GG10-1JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG00-4ER2', '6GK5324-4GG10-4ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-4JR2', '6GK5324-4GG00-4JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-2ER2', '6GK5324-4GG00-2ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG00-2JR2', '6GK5324-4GG10-2JR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-3AR2', '6GK5324-4QG10-3AR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG10-3HR2', '6GK5324-4QG00-3HR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-1AR2', '6GK5324-4QG10-1AR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_rear%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG10-1HR2', '6GK5324-4QG00-1HR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_ts_%2824v%2c_ports_on_front%29_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG10-1CR2', '6GK5324-4QG00-1CR2']},
"cpe:/o:siemens:scalance_xr326-8_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS00-2AR3', '6GK5334-2TS00-4AR3', '6GK5334-2TS00-3AR3']},
"cpe:/o:siemens:scalance_xr326-8_eec_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS00-2ER3']},
"cpe:/o:siemens:scalance_xr502-32_firmware" :
{"family" : "SCALANCEX500", "orderNumbers" : ['6GK5534-5TR00-3AR3', '6GK5534-5TR00-2AR3', '6GK5534-5TR00-4AR3']},
"cpe:/o:siemens:scalance_xr522-12_firmware" :
{"family" : "SCALANCEX500", "orderNumbers" : ['6GK5534-3TR00-4AR3', '6GK5534-3TR00-2AR3', '6GK5534-3TR00-3AR3']},
"cpe:/o:siemens:scalance_xr524-8wg_firmware" :
{"family" : "SCALANCEX500", "orderNumbers" : ['6GK5532-2SR00-3RR3', '6GK5532-2SR00-2RR3', '6GK5532-2SR00-3AR3', '6GK5532-2SR00-2AR3']},
"cpe:/o:siemens:scalance_xr526-8_firmware" :
{"family" : "SCALANCEX500", "orderNumbers" : ['6GK5534-2TR00-3AR3', '6GK5534-2TR00-4AR3', '6GK5534-2TR00-2AR3']},
"cpe:/o:siemens:siplus_net_scalance_x202-2p_irt_firmware" :
{"family" : "SCALANCEX200IRT", "orderNumbers" : ['6AG1202-2BH00-2BA3']},
"cpe:/o:siemens:siplus_net_scalance_x308-2_firmware" :
{"family" : "SCALANCEX300", "orderNumbers" : ['6AG1308-2FL10-4AA3']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation