Siemens SIMATIC S7-1500 Incorrect Calculation of Buffer Size (CVE-2025-0395)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504312);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/17");
script_cve_id("CVE-2025-0395");
script_xref(name:"ICSA", value:"26-134-16");
script_name(english:"Siemens SIMATIC S7-1500 Incorrect Calculation of Buffer Size (CVE-2025-0395)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"When the assert() function in the GNU C Library versions 2.13 to 2.40
fails, it does not allocate enough space for the assertion failure
message string and size information, which may lead to a buffer
overflow if the message string size aligns to page size.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-26-134-16");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-0395");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(131);
script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/12");
script_set_attribute(attribute:"patch_publication_date", value:"2023/12/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
{"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
{"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
17 Jul 2026 00:00Current
6.5Medium risk
Vulners AI Score6.5
CVSS 3.16.2
EPSS0.00356
SSVC