Lucene search
+L

Siemens SIMATIC and SCALANCE Improper Certificate Validation (CVE-2024-8096)

🗓️ 13 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 4 Views

Siemens SIMATIC S7-1500 OCSP stapling CVE-2024-8096 misvalidates certs, treats nonrevoked as valid.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504366);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2024-8096");
  script_xref(name:"ICSA", value:"26-043-06");

  script_name(english:"Siemens SIMATIC and SCALANCE Improper Certificate Validation (CVE-2024-8096)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"When curl is told to use the Certificate Status Request TLS extension,
often referred to as OCSP stapling, to verify that the server
certificate is valid, it might fail to detect some OCSP problems and
instead wrongly consider the response as fine. If the returned status
reports another error than 'revoked' (like for example 'unauthorized')
it is not treated as a bad certficate.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-8096");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(295);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
6.7Medium risk
Vulners AI Score6.7
CVSS 3.16.5
EPSS0.00729
SSVC
4