script_name(english:"Siemens Ruggedcom ROX Uncontrolled Resource Consumption (CVE-2024-7592)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"There is a LOW severity vulnerability affecting CPython, specifically
the 'http.cookies' standard library module. When parsing cookies
that contained backslashes for quoted characters in the cookie value,
the parser would use an algorithm with quadratic complexity, resulting
in excess CPU resources being used while parsing the value.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-202008.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997648/");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-7592");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(400);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/12/09");
script_set_attribute(attribute:"patch_publication_date", value:"2025/12/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/01/09");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
{"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation