#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505106);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");
script_cve_id("CVE-2024-6874");
script_xref(name:"ICSA", value:"26-043-06");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Buffer Over-read (CVE-2024-6874)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"libcurl's URL API function
[curl_url_get()](https://curl.se/libcurl/c/curl_url_get.html) offers
punycode conversions, to and from IDN. Asking to convert a name that
is exactly 256 bytes, libcurl ends up reading outside of a stack based
buffer when built to use the *macidn* IDN backend. The conversion
function then fills up the provided buffer exactly - but does not null
terminate the string. This flaw can lead to stack contents accidently
getting returned as part of the converted string.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997626/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-6874");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(126);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/07/24");
script_set_attribute(attribute:"patch_publication_date", value:"2026/01/28");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xch328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
"cpe:/o:siemens:scalance_xcm324_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
"cpe:/o:siemens:scalance_xcm328_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
"cpe:/o:siemens:scalance_xcm332_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation