Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2024-58079)

🗓️ 20 Oct 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

Improper input validation in Linux kernel media: uvcvideo causes OOPS on unbind.

Related
Refs
Code
ReporterTitlePublishedViews
Family
astralinux
AstraLinux
Astra Linux – Vulnerability found in Linux 6.1, Linux 5.15
14 Sep 202612:41
–astralinux
bdu_fstec
BDU FSTEC
Linux kernel uvcvideo DoS
28 Sep 202500:00
–bdu_fstec
circl
Circl
CVE-2024-58079
6 Mar 202519:41
–circl
cnnvd
CNNVD
Linux Kernel Security Vulnerabilities
6 Mar 202500:00
–cnnvd
cve
CVE
CVE-2024-58079
6 Mar 202516:13
–cve
cvelist
Cvelist
CVE-2024-58079 media: uvcvideo: Fix crash during unbind if gpio unit is in use
6 Mar 202516:13
–cvelist
debian
Debian
[SECURITY] [DLA 4193-1] linux-6.1 security update
29 May 202523:01
–debian
debian
Debian
[SECURITY] [DSA 5900-1] linux security update
12 Apr 202514:25
–debian
debiancve
Debian CVE
CVE-2024-58079
6 Mar 202516:13
–debiancve
nessus
Tenable Nessus
Debian dla-4193 : linux-config-6.1 - security update
29 May 202500:00
–nessus
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(506297);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/10/20");

  script_cve_id("CVE-2024-58079");

  script_name(english:"Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2024-58079)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:

media: uvcvideo: Fix crash during unbind if gpio unit is in use

We used the wrong device for the device managed functions. We used the
usb device, when we should be using the interface device.

If we unbind the driver from the usb interface, the cleanup functions
are never called. In our case, the IRQ is never disabled.

If an IRQ is triggered, it will try to access memory sections that are
already free, causing an OOPS.

We cannot use the function devm_request_threaded_irq here. The devm_*
clean functions may be called after the main structure is released by
uvc_delete.

Luckily this bug has small impact, as it is only affected by devices
with gpio units and the user has to unbind the device, a disconnect will
not trigger this error.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-784472.html");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-58079");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/10/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/10/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/10/20");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
        {"versionEndIncluding" : "1.1.1", "versionStartIncluding" : "1.1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

20 Oct 2026 00:00Current
6.2Medium risk
Vulners AI Score6.2
CVSS 3.15.5 - 7.8
EPSS0.0021
2