| Reporter | Title | Published | Views | Family All 298 |
|---|---|---|---|---|
| Astra Linux – Vulnerability in Linux 6.1 | 11 Feb 202507:35 | – | astralinux | |
| Azure Linux 3.0 Security Update: kernel (CVE-2024-56593) | 20 Mar 202500:00 | – | nessus | |
| Debian dla-4075 : ata-modules-5.10.0-29-armmp-di - security update | 1 Mar 202500:00 | – | nessus | |
| Debian dla-4076 : linux-config-6.1 - security update | 1 Mar 202500:00 | – | nessus | |
| EulerOS 2.0 SP11 : kernel (EulerOS-SA-2025-1359) | 11 Apr 202500:00 | – | nessus | |
| EulerOS 2.0 SP11 : kernel (EulerOS-SA-2025-1360) | 11 Apr 202500:00 | – | nessus | |
| CBL Mariner 2.0 Security Update: kernel (CVE-2024-56593) | 10 Mar 202500:00 | – | nessus | |
| Oracle Linux 8 / 9 : Unbreakable Enterprise kernel (ELSA-2025-20095) | 10 Feb 202500:00 | – | nessus | |
| Oracle Linux 7 / 8 : Unbreakable Enterprise kernel (ELSA-2025-20100) | 13 Feb 202500:00 | – | nessus | |
| Oracle Linux 7 / 8 : Unbreakable Enterprise kernel (ELSA-2025-20153) | 11 Mar 202500:00 | – | nessus |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504530);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");
script_cve_id("CVE-2024-56593");
script_xref(name:"ICSA", value:"25-226-07");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56593)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"wifi: brcmfmac: Fix oops due to NULL pointer dereference in
brcmf_sdiod_sglist_rw(). This patch fixes a NULL pointer dereference
bug in brcmfmac that occurs when a high 'sd_sgentry_align' value
applies (e.g. 512) and a lot of queued SKBs are sent from the pkt
queue.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-56593");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xcm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xch-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrh-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation