CVE-2024-56548: Siemens SCALANCE and RUGGEDCOM improper input validation may cause out-of-bounds writes.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504646);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/13");

  script_cve_id("CVE-2024-56548");
  script_xref(name:"ICSA", value:"25-226-07");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56548)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"hfsplus: Devices block sizes may change. One of these cases is a loop
device by using ioctl LOOP_SET_BLOCK_SIZE. While this may cause other
issues like IO being rejected, in the case of hfsplus, it will
allocate a block by using that size and potentially write out-of-
bounds when hfsplus_read_wrapper calls hfsplus_submit_bio and the
latter function reads a different io_size.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-56548");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
        {"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xcm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xch-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrh-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

13 Mar 2026 00:00Current
6.8Medium risk
Vulners AI Score6.8
CVSS 3.17.8
EPSS0.00247
SSVC
2