Siemens Industrial Edge Devices Weak Authentication (CVE-2024-54092)

🗓️ 28 Oct 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 5 Views

Siemens Industrial Edge devices have weak authentication on API endpoints with identity federation, enabling unauthenticated impersonation.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503757);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/01");

  script_cve_id("CVE-2024-54092");
  script_xref(name:"ICSA", value:"25-100-04");

  script_name(english:"Siemens Industrial Edge Devices Weak Authentication (CVE-2024-54092)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Affected devices do not properly enforce user authentication on
specific API endpoints when identity federation is used. This could
facilitate an unauthenticated remote attacker to circumvent
authentication and impersonate a legitimate user. Successful
exploitation requires that identity federation is currently or has
previously been used and the attacker has learned the identity of a
legitimate user.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-634640.html");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-819629.html");
  # https://docs.industrial-operations-x.siemens.cloud/r/en-us/v3.0/simatic-ipc-ied-os/release-notes
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c7aafe16");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-100-04");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SIMATIC IPC427E Industrial Edge Device: Currently no fix is available
- Industrial Edge Virtual Device: Update to V1.21.1-1-a or later version
- Industrial Edge Own Device (IEOD): Update to V1.21.1-1-a or later version
- SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge
Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device: Update to V3.0 or later version
- Ensure network access to affected products is limited to trusted parties only

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-634640 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-54092");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(1390);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/04/08");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/04/08");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/28");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9413_firmware:1.21.1");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_lpe9413_firmware:1.21.1" :
        {"versionEndExcluding" : "1.21.1", "family" : "SCALANCE", "orderNumbers" : ['6GK5998-3GS01-2AC2']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

01 Apr 2026 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 49.3
CVSS 3.19.8
EPSS0.00744
SSVC
5