Lucene search
+L

Siemens SIPROTEC 5 Devices Use of Default Credentials (CVE-2024-54015)

🗓️ 20 Feb 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 6 Views

Siemens SIPROTEC 5 is vulnerable to unauthorized information retrieval via default credentials.

Related
Refs
Code
ReporterTitlePublishedViews
Family
bdu_fstec
BDU FSTEC
The vulnerability of SIPROTEC relay protection devices lies in the use of default login credentials, which allows attackers to gain unauthorized access to confidential information.
9 Jan 202600:00
bdu_fstec
circl
Circl
CVE-2024-54015
11 Feb 202510:54
circl
cnnvd
CNNVD
Siemens SIPROTEC 5 安全漏洞
11 Feb 202500:00
cnnvd
cve
CVE
CVE-2024-54015
11 Feb 202510:28
cve
cvelist
Cvelist
CVE-2024-54015
11 Feb 202510:28
cvelist
euvd
EUVD
EUVD-2024-52243
3 Oct 202520:07
euvd
ics
ICS
Siemens SIPROTEC 5 Devices
11 Feb 202500:00
ics
ncsc
NCSC
Vulnerabilities fixed in Siemens products
11 Feb 202519:40
ncsc
ncsc
NCSC
Vulnerabilities fixed in Siemens products
14 Feb 202508:46
ncsc
nvd
NVD
CVE-2024-54015
11 Feb 202511:15
nvd
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(502863);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");

  script_cve_id("CVE-2024-54015");
  script_xref(name:"ICSA", value:"25-044-05");

  script_name(english:"Siemens SIPROTEC 5 Devices Use of Default Credentials (CVE-2024-54015)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Affected devices do not properly validate SNMP GET requests. This
could allow an unauthenticated, remote attacker to retrieve sensitive
information of the affected devices with SNMPv2 GET requests using
default credentials.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-767615.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-044-05");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Restrict access to port 161/udp to trusted IP addresses only.
- All affected products: Disable the SNMP service running in the communication modules, if not used.
- SIPROTEC 5 7KE85 (CP300), SIPROTEC 5 7ST85 (CP300), SIPROTEC 5 7ST86 (CP300): Currently no fix is available.
- SIPROTEC 5 Compact 7SX800 (CP050): Update to V9.90 or later version.
- SIPROTEC 5 7SA82 (CP150), SIPROTEC 5 7SD82 (CP150), SIPROTEC 5 7SJ81 (CP150), SIPROTEC 5 7SJ82 (CP150), SIPROTEC 5
7SK82 (CP150), SIPROTEC 5 7SL82 (CP150), SIPROTEC 5 7SX82 (CP150), SIPROTEC 5 7SY82 (CP150), SIPROTEC 5 7UT82 (CP150):
Update to V9.90 or later version.
- SIPROTEC 5 6MD84 (CP300), SIPROTEC 5 6MD85 (CP300), SIPROTEC 5 6MD86 (CP300), SIPROTEC 5 6MD89 (CP300), SIPROTEC 5
6MU85 (CP300), SIPROTEC 5 7SA86 (CP300), SIPROTEC 5 7SA87 (CP300), SIPROTEC 5 7SD86 (CP300), SIPROTEC 5 7SD87 (CP300),
SIPROTEC 5 7SJ85 (CP300), SIPROTEC 5 7SJ86 (CP300), SIPROTEC 5 7SK85 (CP300), SIPROTEC 5 7SL86 (CP300), SIPROTEC 5 7SL87
(CP300), SIPROTEC 5 7SS85 (CP300), SIPROTEC 5 7SX85 (CP300), SIPROTEC 5 7UM85 (CP300), SIPROTEC 5 7UT85 (CP300),
SIPROTEC 5 7UT86 (CP300), SIPROTEC 5 7UT87 (CP300), SIPROTEC 5 7VE85 (CP300), SIPROTEC 5 7VK87 (CP300), SIPROTEC 5 7VU85
(CP300): Update to V9.90 or later version.
- SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2), SIPROTEC 5
Communication Module ETH-BD-2FO: Update to V9.90 or later version.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-767615 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-54015");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_cwe_id(1392);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/02/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/02/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/02/20");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:siprotec_5_7ke85_%28cp300%29_firmware" :
        {"versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7st85_%28cp300%29_firmware" :
        {"versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7st86_%28cp300%29_firmware" :
        {"family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_compact_7sx800_%28cp050%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "9.50", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj81_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sk82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sx82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sy82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut82_%28cp150%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md84_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6md89_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_6mu85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sa87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sd87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sj86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sk85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sl87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ss85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7sx85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7um85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut86_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ut87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7ve85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7vk87_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "versionStartIncluding" : "8.80", "family" : "Siprotec5"},
    "cpe:/o:siemens:siprotec_5_7vu85_%28cp300%29_firmware" :
        {"versionEndExcluding" : "9.90", "family" : "Siprotec5"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

14 Feb 2026 00:00Current
5.6Medium risk
Vulners AI Score5.6
CVSS 3.17.5
CVSS 48.7
EPSS0.00572
SSVC
6