Lucene search
+L

Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53158)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

Siemens SCALANCE and RUGGEDCOM devices have improper input validation causing array underflow in clock table retrieval (CVE-2024-53158).

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504518);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");

  script_cve_id("CVE-2024-53158");
  script_xref(name:"ICSA", value:"25-226-07");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53158)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"soc: qcom: geni-se: array underflow in geni_se_clk_tbl_get() This loop
is supposed to break if the frequency returned from clk_round_rate()
is the same as on the previous iteration. However, that check doesn't
make sense on the first iteration through the loop. It leads to
reading before the start of these->clk_perf_tbl[] array.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-53158");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
        {"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xcm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xch-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrh-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

12 Feb 2026 00:00Current
6.7Medium risk
Vulners AI Score6.7
CVSS 3.15.5
EPSS0.00265
SSVC
2