Siemens SIMATIC S7-1200 CPUs Cross-Site Request Forgery (CVE-2024-47100)
| Reporter | Title | Published | Views | Family All 13 |
|---|---|---|---|---|
| The vulnerability of the web interface of microprogramming software for programmable logic controllers SIMATIC S7-1200 allows a attacker to perform a CSRF attack. | 14 Feb 202500:00 | – | bdu_fstec | |
| CVE-2024-47100 | 14 Jan 202510:32 | – | circl | |
| Siemens SIMATIC S7-1200 跨站请求伪造漏洞 | 14 Jan 202500:00 | – | cnnvd | |
| Siemens SIMATIC S7-1200 CPU Cross-Site Request Forgery Vulnerability | 14 Jan 202500:00 | – | cnvd | |
| CVE-2024-47100 | 14 Jan 202510:30 | – | cve | |
| CVE-2024-47100 | 14 Jan 202510:30 | – | cvelist | |
| EUVD-2024-42311 | 3 Oct 202520:07 | – | euvd | |
| Siemens SIMATIC S7-1200 CPUs | 14 Jan 202500:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 14 Jan 202511:54 | – | ncsc | |
| CVE-2024-47100 | 14 Jan 202511:15 | – | nvd |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502813);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");
script_cve_id("CVE-2024-47100");
script_xref(name:"ICSA", value:"25-021-02");
script_name(english:"Siemens SIMATIC S7-1200 CPUs Cross-Site Request Forgery (CVE-2024-47100)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The web interface of the affected devices is vulnerable to Cross-Site
Request Forgery (CSRF) attacks. This could allow an unauthenticated
attacker to change the CPU mode by tricking a legitimate and
authenticated user with sufficient permissions on the target CPU to
click on a malicious link.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-717113.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109976907/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-02");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has released new versions for the affected products and recommends updating to the latest versions:
- SIMATIC S7-1200 CPU: Update to V4.7 or later version.
- SIPLUS S7-1200 CPU: Update to V4.7 or later version.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- Do not click on links from untrusted sources.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-717113 in HTML and CSAF.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:P/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-47100");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(352);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/01/14");
script_set_attribute(attribute:"patch_publication_date", value:"2025/01/14");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/01/22");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1200_cpu_firmware:4.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1200_cpu_firmware:4.7");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:siplus_s7-1200_cpu_firmware:4.7" :
{"versionEndExcluding" : "4.7", "family" : "S71200", "orderNumbers" : ['6AG1215-1HG40-4XB0', '6AG1215-1AG40-5XB0', '6AG1215-1BG40-4XB0', '6AG1214-1AG40-2XB0', '6AG1215-1HG40-5XB0', '6AG1214-1BG40-2XB0', '6AG1214-1HG40-2XB0', '6AG1215-1BG40-5XB0', '6AG1212-1BE40-2XB0', '6AG1215-1BG40-2XB0', '6AG1212-1BE40-4XB0', '6AG1214-1AG40-5XB0', '6AG1215-1AG40-2XB0', '6AG1212-1AE40-2XB0', '6AG1212-1HE40-2XB0', '6AG1214-1HG40-5XB0', '6AG1212-1AE40-4XB0', '6AG1215-1AF40-5XB0', '6AG1214-1HG40-4XB0', '6AG2212-1AE40-1XB0', '6AG1214-1HF40-5XB0', '6AG1215-1AG40-4XB0', '6AG1214-1BG40-5XB0', '6AG1212-1HE40-4XB0', '6AG1215-1HG40-2XB0', '6AG2214-1AG40-1XB0', '6AG1214-1BG40-4XB0', '6AG1214-1AG40-4XB0', '6AG1214-1AF40-5XB0']},
"cpe:/o:siemens:simatic_s7-1200_cpu_firmware:4.7" :
{"versionEndExcluding" : "4.7", "family" : "S71200", "orderNumbers" : ['6ES7211-1AE40-0XB0', '6ES7212-1HE40-0XB0', '6ES7212-1AE40-0XB0', '6ES7215-1AF40-0XB0', '6ES7214-1AG40-0XB0', '6ES7211-1BE40-0XB0', '6ES7215-1HG40-0XB0', '6ES7217-1AG40-0XB0', '6ES7215-1HF40-0XB0', '6ES7214-1HF40-0XB0', '6ES7214-1BG40-0XB0', '6ES7215-1AG40-0XB0', '6ES7214-1AF40-0XB0', '6ES7211-1HE40-0XB0', '6ES7212-1AF40-0XB0', '6ES7215-1BG40-0XB0', '6ES7212-1HF40-0XB0', '6ES7214-1HG40-0XB0', '6ES7212-1BE40-0XB0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
14 Feb 2026 00:00Current
5.5Medium risk
Vulners AI Score5.5
CVSS 3.17.1
CVSS 47.2
EPSS0.00238
SSVC