| Reporter | Title | Published | Views | Family All 153 |
|---|---|---|---|---|
| Astra Linux – Vulnerability found in Linux 5.10, Linux 6.1 | 20 May 202605:53 | – | astralinux | |
| The vulnerability of the Linux operating system’s USB kernel component, which allows a hacker to cause a service failure | 24 Feb 202500:00 | – | bdu_fstec | |
| CVE-2024-44960 affecting package kernel for versions less than 5.15.167.1-1 | 12 Oct 202402:07 | – | cbl_mariner | |
| CVE-2024-44960 | 4 Sep 202421:56 | – | circl | |
| Linux kernel 安全漏洞 | 4 Sep 202400:00 | – | cnnvd | |
| CVE-2024-44960 | 4 Sep 202418:35 | – | cve | |
| CVE-2024-44960 usb: gadget: core: Check for unset descriptor | 4 Sep 202418:35 | – | cvelist | |
| [SECURITY] [DLA 3912-1] linux security update | 7 Oct 202418:20 | – | debian | |
| [SECURITY] [DLA 4008-1] linux-6.1 security update | 3 Jan 202500:41 | – | debian | |
| CVE-2024-44960 | 4 Sep 202418:35 | – | debiancve |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503632);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/12");
script_cve_id("CVE-2024-44960");
script_xref(name:"ICSA", value:"25-226-07");
script_name(english:"Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-44960)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"usb: gadget: core: Check for unset descriptor. It needs to be
reassured that the descriptor has been set before looking at
maxpacket. This fixes a null pointer panic in this case. This may
happen if the gadget doesn't properly set up the endpoint for the
current speed, or the gadget descriptors are malformed and the
descriptor for the speed/endpoint are not found. No current gadget
driver is known to have this problem, but this may cause a hard-to-
find bug during development of new gadgets.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-265688.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.2 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-44960");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"patch_publication_date", value:"2024/04/09");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/27");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_tm_mfp");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_tm_mfp" :
{"versionEndIncluding" : "1.1", "versionStartIncluding" : "1.1", "family" : "S71500", "orderNumbers": ["6ES7558-1AA00-0AB0"]},
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
{"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xr-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xc-400_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
"cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xr-500_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
"cpe:/o:siemens:scalance_xcm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrm-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xch-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xrh-300_series_firmware" :
{"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation