Lucene search
+L

Siemens SCALANCE and RUGGEDCOM Devices Improper Control of Resource Identifiers ('Resource Injection') (CVE-2024-42244)

🗓️ 18 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 6 Views

CVE-2024-42244: Improper control of resource identifiers on Siemens SCALANCE and RUGGEDCOM devices.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504752);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/12");

  script_cve_id("CVE-2024-42244");
  script_xref(name:"ICSA", value:"25-226-07");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Control of Resource Identifiers ('Resource Injection') (CVE-2024-42244)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"USB: serial: mos7840: fix crash on resume Since(USB: serial: use
generic method if no alternative is provided in usb serial layer),
USB serial core calls the generic resume implementation when the
driver has not provided one. This can trigger a crash on resume with
mos7840 since support for multiple read URBs was added back in 2011.
Specifically, both port read URBs are now submitted on resume for open
ports, but the context pointer of the second URB is left set to the
core rather than mos7840 port structure.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-355557.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109988839/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-42244");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(99);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/08/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/18");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh-300_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2" :
        {"versionEndExcluding" : "3.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xcm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrm-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xch-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xrh-300_series_firmware" :
        {"versionEndExcluding" : "3.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

12 Mar 2026 00:00Current
6.8Medium risk
Vulners AI Score6.8
CVSS 3.15.5
EPSS0.00229
SSVC
6