Siemens SCALANCE and RUGGEDCOM Devices Improper Locking (CVE-2024-26925)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502670);
script_version("1.5");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/12/24");
script_cve_id("CVE-2024-26925");
script_xref(name:"ICSA", value:"24-319-06");
script_name(english:"Siemens SCALANCE and RUGGEDCOM Devices Improper Locking (CVE-2024-26925)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
netfilter: nf_tables: release mutex after nft_gc_seq_end from abort
path The commit mutex should not be released during the critical
section between nft_gc_seq_begin() and nft_gc_seq_end(), otherwise,
async GC worker could collect expired objects and get the released
commit lock within the same GC sequence. nf_tables_module_autoload()
temporarily releases the mutex to load module dependencies, then it
goes back to replay the transaction again. Move it at the end of the
abort phase after nft_gc_seq_end() is called.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-354112.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109976047/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-319-06");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-26925");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(667);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/11/12");
script_set_attribute(attribute:"patch_publication_date", value:"2024/11/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/11/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_eu_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_nam_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m804pb_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m812-1_adsl-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m816-1_adsl-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m826-2_shdsl-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-2_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-3_3g-router_%28cn%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m874-3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-3_%28rok%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-3_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_%28nam%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m876-4_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28a1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28b1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum853-1_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28a1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28b1%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28cn%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28eu%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_mum856-1_%28row%29_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_s615_eec_lan-router_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_s615_lan-router_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2024-2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_eu_firmware" :
{"versionEndExcluding" : "8.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6108-4AM00-2BA2']},
"cpe:/o:siemens:ruggedcom_rm1224_lte%284g%29_nam_firmware" :
{"versionEndExcluding" : "8.2", "family" : "RuggedCom", "orderNumbers" : ['6GK6108-4AM00-2DA2']},
"cpe:/o:siemens:scalance_m804pb_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5804-0AP00-2AA2']},
"cpe:/o:siemens:scalance_m812-1_adsl-router_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5812-1BA00-2AA2', '6GK5812-1AA00-2AA2']},
"cpe:/o:siemens:scalance_m816-1_adsl-router_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5816-1AA00-2AA2', '6GK5816-1BA00-2AA2']},
"cpe:/o:siemens:scalance_m826-2_shdsl-router_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5826-2AB00-2AB2']},
"cpe:/o:siemens:scalance_m874-2_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5874-2AA00-2AA2']},
"cpe:/o:siemens:scalance_m874-3_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5874-3AA00-2AA2']},
"cpe:/o:siemens:scalance_m874-3_3g-router_%28cn%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5874-3AA00-2FA2']},
"cpe:/o:siemens:scalance_m876-3_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5876-3AA02-2BA2']},
"cpe:/o:siemens:scalance_m876-3_%28rok%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5876-3AA02-2EA2']},
"cpe:/o:siemens:scalance_m876-4_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA10-2BA2']},
"cpe:/o:siemens:scalance_m876-4_%28eu%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA00-2BA2']},
"cpe:/o:siemens:scalance_m876-4_%28nam%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5876-4AA00-2DA2']},
"cpe:/o:siemens:scalance_mum853-1_%28a1%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA10-2AA1']},
"cpe:/o:siemens:scalance_mum853-1_%28b1%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA10-2BA1']},
"cpe:/o:siemens:scalance_mum853-1_%28eu%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5853-2EA00-2DA1']},
"cpe:/o:siemens:scalance_mum856-1_%28a1%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA10-3AA1']},
"cpe:/o:siemens:scalance_mum856-1_%28b1%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA10-3BA1']},
"cpe:/o:siemens:scalance_mum856-1_%28cn%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3FA1']},
"cpe:/o:siemens:scalance_mum856-1_%28eu%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3DA1']},
"cpe:/o:siemens:scalance_mum856-1_%28row%29_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCEM", "orderNumbers" : ['6GK5856-2EA00-3AA1']},
"cpe:/o:siemens:scalance_s615_eec_lan-router_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCES", "orderNumbers" : ['6GK5615-0AA01-2AA2']},
"cpe:/o:siemens:scalance_s615_lan-router_firmware" :
{"versionEndExcluding" : "8.2", "family" : "SCALANCES", "orderNumbers" : ['6GK5615-0AA00-2AA2']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
24 Dec 2025 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 3.15.5 - 7.8
EPSS0.00267
SSVC