Siemens SIMATIC S7-1500 Concurrent Execution using Shared Resource with Improper Synchronization (CVE-2024-26671)
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(504320);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");
script_cve_id("CVE-2024-26671");
script_xref(name:"ICSA", value:"25-226-15");
script_name(english:"Siemens SIMATIC S7-1500 Concurrent Execution using Shared Resource with Improper Synchronization (CVE-2024-26671)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"In the Linux kernel, the following vulnerability has been resolved:
blk-mq: fix IO hang from sbitmap wakeup race.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-613116.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109977557/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.1 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
For more information, see the associated Siemens security advisory in HTML and CSAF.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-26671");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(362);
script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/12");
script_set_attribute(attribute:"patch_publication_date", value:"2023/12/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.1");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300%2fxr-300%2fxc-400%2fxr-500wg%2fxr-500_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm-%2fxrm-%2fxch-%2fxrh-300_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
{"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
{"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']},
"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.1" :
{"versionEndExcluding" : "3.1", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
"cpe:/o:siemens:scalance_xc-300%2fxr-300%2fxc-400%2fxr-500wg%2fxr-500_series_firmware" :
{"versionEndExcluding" : "3.1", "family" : "SCALANCEX300"},
"cpe:/o:siemens:scalance_xcm-%2fxrm-%2fxch-%2fxrh-300_series_firmware" :
{"versionEndExcluding" : "3.1", "family" : "SCALANCEX"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
05 Mar 2026 00:00Current
6.3Medium risk
Vulners AI Score6.3
CVSS 3.14.7
EPSS0.00186
SSVC