Lucene search
+L

Siemens SIMATIC S7-1500 and Ruggedcom ROX Devices Inefficient Algorithmic Complexity (CVE-2024-12243)

🗓️ 13 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

Siemens SIMATIC S7-1500 vulnerable to DoS via GnuTLS libtasn1 DER certificates (CVE-2024-12243).

Related
Refs
Code
ReporterTitlePublishedViews
Family
ibm
IBM Security Bulletins
Security Bulletin: Security vulnerabilities affect multiple packages shipped with IBM CICS TX Advanced.
28 Apr 202510:33
ibm
ibm
IBM Security Bulletins
Security Bulletin: IBM Watson Speech Services Cartridge is vulnerable to multiple Base OS issues
28 Aug 202521:17
ibm
ibm
IBM Security Bulletins
Security Bulletin: Security vulnerabilities have been found in IBM Verify Identity Access and IBM Security Verify Access
5 Jan 202600:41
ibm
ibm
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities in IBM MQ Operator and Queue manager container images
15 Jun 202513:39
ibm
ibm
IBM Security Bulletins
Security Bulletin: A vulnerability in RedHat UBI affects IBM Robotic Process Automation for Cloud Pak and may result in denial of service (CVE-2024-12243).
10 Dec 202513:53
ibm
ibm
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities in IBM Observability with Instana (OnPrem)
21 Oct 202514:44
ibm
ibm
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities found in IBM TXSeries for Multiplatforms.
7 Jul 202514:23
ibm
ibm
IBM Security Bulletins
Security Bulletin: IBM Watson Speech Services Cartridge is vulnerable to multiple Operator package issues
28 Aug 202521:18
ibm
ibm
IBM Security Bulletins
Security Bulletin: IBM App Connect Enterprise Certified Container UBI updates
30 Jun 202513:27
ibm
ibm
IBM Security Bulletins
Security Bulletin: IBM Instana Observability is affected by multiple vulnerabilities within Instana Agent container image
3 Jul 202510:30
ibm
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503956);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");

  script_cve_id("CVE-2024-12243");
  script_xref(name:"ICSA", value:"25-162-05");
  script_xref(name:"ICSA", value:"23-348-10");

  script_name(english:"Siemens SIMATIC S7-1500 and Ruggedcom ROX Devices Inefficient Algorithmic Complexity (CVE-2024-12243)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A flaw was found in GnuTLS, which relies on libtasn1 for ASN.1 data
processing. Due to an inefficient algorithm in libtasn1, decoding
certain DER-encoded certificate data can take excessive time, leading
to increased resource consumption. This flaw allows a remote attacker
to send a specially crafted certificate, causing GnuTLS to become
unresponsive or slow, resulting in a denial-of-service condition.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-082556.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-05");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens is preparing fixed versions and reports that currently, no fix is available.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-082556 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-12243");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(407);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/06/10");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/06/10");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
        {"versionStartIncluding" : "3.1.5", "family" : "S71500", "orderNumbers" : ['6ES7518-4FX00-1AB0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
        {"versionStartIncluding" : "3.1.5", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']},
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

14 Feb 2026 00:00Current
6.6Medium risk
Vulners AI Score6.6
CVSS 3.15.3
EPSS0.01245
SSVC
2