Lucene search

K
nessusThis script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2023-45625.NASL
HistoryApr 13, 2024 - 12:00 a.m.

Siemens Scalance W1750D Improper Neutralization of Special Elements used in a Command (CVE-2023-45625)

2024-04-1300:00:00
This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8
siemens
scalance w1750d
command injection
vulnerability
cve-2023-45625
execution
arbitrary commands
privileged user
tenable.ot

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

8.3 High

AI Score

Confidence

Low

0.002 Low

EPSS

Percentile

56.3%

Multiple authenticated command injection vulnerabilities exist in the command line interface. Successful exploitation of these vulnerabilities result in the ability to execute arbitrary commands as a privileged user on the underlying operating system.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(502201);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/04/17");

  script_cve_id("CVE-2023-45625");

  script_name(english:"Siemens Scalance W1750D Improper Neutralization of Special Elements used in a Command (CVE-2023-45625)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Multiple authenticated command injection vulnerabilities exist in the
command line interface. Successful exploitation of these
vulnerabilities result in the ability to execute arbitrary commands as
a privileged user on the underlying operating system.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2023-017.txt");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-716164.html");
  script_set_attribute(attribute:"solution", value:
"Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:

- CVE-2023-45614, CVE-2023-45615, CVE-2023-45616, CVE-2023-45617, CVE-2023-45618, CVE-2023-45619, 
CVE-2023-45620, CVE-2023-45621, CVE-2023-45622, CVE-2023-45623, CVE-2023-45624: 
Enabling cluster-security via the cluster-security command will prevent the vulnerabilities 
from being exploited 
- CVE-2023-45625, CVE-2023-45626, CVE-2023-45627: The CLI and web-based management interfaces should 
be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above 

Product-specific remediations or mitigations can be found in the section Affected Products and Solution 
of the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-45625");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(77);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/11/14");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/11/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/04/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1750d_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_w1750d_firmware" :
        {"versionEndExcluding" : "8.10.0.9", "family" : "SCALANCEW", "orderNumbers" : ["6GK5750-2HX01-1AD0","6GK5750-2HX01-1AA0","6GK5750-2HX01-1AB0"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemensscalance_w1750d_firmwarecpe:/o:siemens:scalance_w1750d_firmware

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

8.3 High

AI Score

Confidence

Low

0.002 Low

EPSS

Percentile

56.3%

Related for TENABLE_OT_SIEMENS_CVE-2023-45625.NASL