Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2023-25139)

🗓️ 13 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 7 Views

Siemens S7-1500 out-of-bounds write via glibc buffer sizing edge case CVE-2023-25139.

Related
Refs
Code
ReporterTitlePublishedViews
Family
alpinelinux
AlpineLinux
CVE-2023-25139
3 Feb 202300:00
alpinelinux
bdu_fstec
BDU FSTEC
The vulnerability of the sprintf function in the GNU C library (glibc) allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.
6 Mar 202300:00
bdu_fstec
cgr
Chainguard
CVE-2023-25139 vulnerabilities
3 Feb 202306:15
cgr
circl
Circl
CVE-2023-25139
3 Feb 202312:20
circl
cnnvd
CNNVD
GNU C Library 缓冲区错误漏洞
3 Feb 202300:00
cnnvd
cve
CVE
CVE-2023-25139
3 Feb 202300:00
cve
cvelist
Cvelist
CVE-2023-25139
3 Feb 202300:00
cvelist
debiancve
Debian CVE
CVE-2023-25139
3 Feb 202300:00
debiancve
euvd
EUVD
EUVD-2023-29118
3 Oct 202520:07
euvd
f5
F5 Networks
K000135880: glibc vulnerability CVE-2023-25139
16 Aug 202318:29
f5
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504241);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2023-25139");
  script_xref(name:"ICSA", value:"23-348-10");

  script_name(english:"Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2023-25139)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"sprintf in the GNU C Library (glibc) 2.37 has a buffer overflow (out-
of-bounds write) in some situations with a correct buffer size. This
is unrelated to CWE-676. It may write beyond the bounds of the
destination buffer when attempting to write a padded, thousands-
separated string representation of a number, if the buffer is
allocated the exact size required to represent that number as a
string. For example, 1,234,567 (with padding to 13) overflows by two
bytes.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0): Only build and run applications from trusted sources.
Currently no fix is available.

Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions prior to V3.1 refer to
SiemensSecurity Bulletin SSB-439005.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-398330 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-25139");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(787);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/12/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
7.3High risk
Vulners AI Score7.3
CVSS 3.19.8
EPSS0.01423
SSVC
7