| Reporter | Title | Published | Views | Family All 33 |
|---|---|---|---|---|
| Amazon Linux 2023 : p7zip, p7zip-plugins (ALAS2023-2024-481) | 8 Jan 202400:00 | – | nessus | |
| Debian dla-4576 : p7zip - security update | 11 May 202600:00 | – | nessus | |
| SUSE SLED15 / SLES15 / openSUSE 15 Security Update : p7zip (SUSE-SU-2025:3791-1) | 25 Oct 202500:00 | – | nessus | |
| Linux Distros Unpatched Vulnerability : CVE-2022-47069 | 27 Aug 202500:00 | – | nessus | |
| Medium: p7zip | 8 Jan 202400:00 | – | amazon | |
| Medium: p7zip | 8 Jan 202400:00 | – | amazon | |
| Medium: p7zip | 6 Mar 202400:00 | – | amazon | |
| CVE-2022-47069 | 22 Aug 202319:16 | – | alpinelinux | |
| The vulnerability of the NArchive::NZip::CInArchive::FindCd function of the p7zip archive tool can potentially affect the confidentiality, integrity, and accessibility of the protected information. | 24 Apr 202500:00 | – | bdu_fstec | |
| CVE-2022-47069 | 22 Aug 202322:18 | – | circl |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502906);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");
script_cve_id("CVE-2022-47069");
script_xref(name:"ICSA", value:"25-044-09");
script_name(english:"Siemens SCALANCE W700 Out-of-bounds Write (CVE-2022-47069)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"p7zip 16.02 was discovered to contain a heap-buffer-overflow
vulnerability via the function
NArchive::NZip::CInArchive::FindCd(bool) at
CPP/7zip/Archive/Zip/ZipIn.cpp.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-769027.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109977720/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-044-09");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Update to V3.0.0 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage
For more information see the associated Siemens security advisory SSA-769027 in HTML and CSAF.");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-47069");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(787);
script_set_attribute(attribute:"vuln_publication_date", value:"2025/02/11");
script_set_attribute(attribute:"patch_publication_date", value:"2025/02/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/02/24");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wab762-1_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_%28me%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_%28us%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28me%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28me%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wub762-1_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wub762-1_ifeatures_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum763-1_%28us%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum763-1_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28me%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28usa%29_firmware:3.0.0");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_firmware:3.0.0");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:scalance_wab762-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-6AA0']},
"cpe:/o:siemens:scalance_wam763-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DA0']},
"cpe:/o:siemens:scalance_wam763-1_%28me%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DC0']},
"cpe:/o:siemens:scalance_wam763-1_%28us%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DB0']},
"cpe:/o:siemens:scalance_wam766-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DA0']},
"cpe:/o:siemens:scalance_wam766-1_%28me%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DC0']},
"cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DB0']},
"cpe:/o:siemens:scalance_wam766-1_eec_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TA0']},
"cpe:/o:siemens:scalance_wam766-1_eec_%28me%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TC0']},
"cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TB0']},
"cpe:/o:siemens:scalance_wub762-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-1AA0']},
"cpe:/o:siemens:scalance_wub762-1_ifeatures_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5762-1AJ00-2AA0']},
"cpe:/o:siemens:scalance_wum763-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-3AA0', '6GK5763-1AL00-3DA0']},
"cpe:/o:siemens:scalance_wum763-1_%28us%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-3DB0', '6GK5763-1AL00-3AB0']},
"cpe:/o:siemens:scalance_wum766-1_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DA0']},
"cpe:/o:siemens:scalance_wum766-1_%28me%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DC0']},
"cpe:/o:siemens:scalance_wum766-1_%28usa%29_firmware:3.0.0" :
{"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DB0']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation