HistoryJan 25, 2023 - 12:00 a.m.

Siemens Desigo PXM Devices Cross-Site Request Forgery (CVE-2022-40179)

2023-01-2500:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
23
cross-site request forgery
siemens
desigo pxm
cve-2022-40179
endpoint security
axon language

8.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

35.0%

A vulnerability has been identified in Desigo PXM30-1 (All versions < V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41), Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All versions < V02.20.126.11-41), Desigo PXM50-1 (All versions < V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41), PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All versions < V02.20.126.11-41), PXG3.W200-1 (All versions < V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41). A Cross-Site Request Forgery exists in endpoints of the Operation web application that interpret and execute Axon language queries, due to the missing validation of anti-CSRF tokens or other origin checks. By convincing a victim to click on a malicious link or visit a specifically crafted webpage while logged-in to the device web application, a remote unauthenticated attacker can execute arbitrary Axon queries against the device.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500745);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/04/11");

  script_cve_id("CVE-2022-40179");

  script_name(english:"Siemens Desigo PXM Devices Cross-Site Request Forgery (CVE-2022-40179)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in Desigo PXM30-1 (All versions <
V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41),
Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All
versions < V02.20.126.11-41), Desigo PXM50-1 (All versions <
V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41),
PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All
versions < V02.20.126.11-41), PXG3.W200-1 (All versions <
V02.20.126.11-37), PXG3.W200-2 (All versions < V02.20.126.11-41). A
Cross-Site Request Forgery exists in endpoints of the Operation web
application that interpret and execute Axon language queries, due to
the missing validation of anti-CSRF tokens or other origin checks. By
convincing a victim to click on a malicious link or visit a
specifically crafted webpage while logged-in to the device web
application, a remote unauthenticated attacker can execute arbitrary
Axon queries against the device.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-360783.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-06");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released updates for the affected products and recommends users update to the latest versions:

- Desigo PXM30-1: Update to V02.20.126.11-41 or later
- Desigo PXM30.E: Update to V02.20.126.11-41 or later
- Desigo PXM40-1: Update to V02.20.126.11-41 or later
- Desigo PXM40.E: Update to V02.20.126.11-41 or later
- Desigo PXM50-1: Update to V02.20.126.11-41 or later
- Desigo PXM50.E: Update to V02.20.126.11-41 or later
- PXG3.W100-1: Update to V02.20.126.11-37 or later
- PXG3.W100-2: Update to V02.20.126.11-41 or later
- PXG3.W200-1: Update to V02.20.126.11-37 or later
- PXG3.W200-2: Update to V02.20.126.11-41 or later

 As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to SiemensҀ™
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information, see the associated Siemens Security Advisory in HTML or CSAF formats.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-40179");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(352);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/10/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/10/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/01/25");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm30-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm30.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm40-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm40.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm50-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:desigo_pxm50.e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w100-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w100-2_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w200-1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:pxg3.w200-2_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:desigo_pxm30-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm30.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm40-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm40.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm50-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:desigo_pxm50.e_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w100-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-37", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w100-2_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w200-1_firmware" :
        {"versionEndExcluding" : "02.20.126.11-37", "family" : "Desigo"},
    "cpe:/o:siemens:pxg3.w200-2_firmware" :
        {"versionEndExcluding" : "02.20.126.11-41", "family" : "Desigo"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemensdesigo_pxm30-1_firmwarecpe:/o:siemens:desigo_pxm30-1_firmware
siemensdesigo_pxm30.e_firmwarecpe:/o:siemens:desigo_pxm30.e_firmware
siemensdesigo_pxm40-1_firmwarecpe:/o:siemens:desigo_pxm40-1_firmware
siemensdesigo_pxm40.e_firmwarecpe:/o:siemens:desigo_pxm40.e_firmware
siemensdesigo_pxm50-1_firmwarecpe:/o:siemens:desigo_pxm50-1_firmware
siemensdesigo_pxm50.e_firmwarecpe:/o:siemens:desigo_pxm50.e_firmware
siemenspxg3.w100-1_firmwarecpe:/o:siemens:pxg3.w100-1_firmware
siemenspxg3.w100-2_firmwarecpe:/o:siemens:pxg3.w100-2_firmware
siemenspxg3.w200-1_firmwarecpe:/o:siemens:pxg3.w200-1_firmware
siemenspxg3.w200-2_firmwarecpe:/o:siemens:pxg3.w200-2_firmware

8.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

35.0%

Related for TENABLE_OT_SIEMENS_CVE-2022-40179.NASL