6

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x:
6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501045);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/08/18");

  script_cve_id("CVE-2022-37888");

  script_name(english:"Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2022-37888)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"There are buffer overflow vulnerabilities in multiple underlying
services that could lead to unauthenticated remote code execution by
sending specially crafted packets destined to the PAPI (Aruba Networks
AP management protocol) UDP port (8211). Successful exploitation of
these vulnerabilities results in the ability to execute arbitrary code
as a privileged user on the underlying operating system of Aruba
InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x:
6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba
InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1
and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released
upgrades for Aruba InnstantOS that address these security
vulnerabilities.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-10");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens identified the following specific workarounds and mitigations to reduce risk: 

- CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, and CVE-2022-37889: Enable CPSec via the cluster-
security command.
- CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, and CVE-2022-37896: Restrict the web-based management
interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above.
- CVE-2022-37893: Restrict the command line interface to a dedicated layer 2 segment/VLAN and/or control the interface
by firewall policies at layer 3 and above.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In
order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to
Siemens' operational guidelines for industrial security and following the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at the Siemens website.

For more information, see the associated Siemens security advisory SSA-506569 in HTML and CSAF. 

Siemens SCALANCE W1750D is a brand-labeled device from Aruba. For more information regarding these vulnerabilities, see
the Aruba security advisory ARUBA-PSA-2022-014.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-37888");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(120);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/10/06");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/10/06");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/04/11");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1750d_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_w1750d_firmware" :
        {"versionEndExcluding" : "8.7.1.11", "family" : "SCALANCEW"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemensscalance_w1750d_firmwarecpe:/o:siemens:scalance_w1750d_firmware
Related for TENABLE_OT_SIEMENS_CVE-2022-37888.NASL