Siemens SCALANCE XCM332 Improper Validation of Syntactic Correctness of Input (CVE-2022-35252)

2023-05-0200:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
13
siemens
scalance xcm332
vulnerability
cve-2022-35252
validation
http
denial of service
tenable.ot
cisa
industrial security
exploit

EPSS

0.001

Percentile

50.8%

When curl is used to retrieve and parse cookies from a HTTP(S) server, itaccepts cookies using control codes that when later are sent back to a HTTPserver might make the server return 400 responses. Effectively allowing asister site to deny service to all siblings.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501082);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/07/24");

  script_cve_id("CVE-2022-35252");
  script_xref(name:"GLSA", value:"GLSA-202212-01");

  script_name(english:"Siemens SCALANCE XCM332 Improper Validation of Syntactic Correctness of Input (CVE-2022-35252)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"When curl is used to retrieve and parse cookies from a HTTP(S) server,
itaccepts cookies using control codes that when later are sent back to
a HTTPserver might make the server return 400 responses. Effectively
allowing asister site to deny service to all siblings.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-09
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?4af41997");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-558014.html");
  script_set_attribute(attribute:"see_also", value:"https://hackerone.com/reports/1613943");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20220930-0005/");
  script_set_attribute(attribute:"see_also", value:"https://security.gentoo.org/glsa/202212-01");
  script_set_attribute(attribute:"see_also", value:"https://support.apple.com/kb/HT213604");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-09");
  script_set_attribute(attribute:"see_also", value:"https://support.apple.com/kb/HT213603");
  script_set_attribute(attribute:"see_also", value:"http://seclists.org/fulldisclosure/2023/Jan/21");
  script_set_attribute(attribute:"see_also", value:"http://seclists.org/fulldisclosure/2023/Jan/20");
  script_set_attribute(attribute:"see_also", value:"https://lists.debian.org/debian-lts-announce/2023/01/msg00028.html");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released an update for the SCALANCE XCM332 and recommends updating to the latest version: 

- SCALANCE XCM332 (6GK5332-0GA01-2AC2): Update to V2.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’
operational guidelines for industrial security and following the recommendations in the product manuals. Additional
information on Industrial Security by Siemens can be found at the Siemens Industrial Security web page.

For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens
ProductCERT.

For more information see the associated Siemens security advisory SSA-558014 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:H/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-35252");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/09/23");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/09/23");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/05/02");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_xcm332_firmware" :
        {"versionEndExcluding" : "2.2", "family" : "SCALANCEX300"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_NOTE);