Lucene search
+L

Siemens Ruggedcom ROX Improper Neutralization of Special Elements in Output Used by a Downstream Component (CVE-2022-34903)

🗓️ 09 Jan 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 7 Views

CVE-2022-34903 permits GnuPG signature forgery with secret keys, affecting Siemens Ruggedcom ROX.

Related
Refs
Code
ReporterTitlePublishedViews
Family
IBM Security Bulletins
Security Bulletin: IBM Watson Discovery for IBM Cloud Pak for Data affected by vulnerability in GnuPG [CVE-2022-3515 and CVE-2022-34903]
30 Nov 202210:22
ibm
IBM Security Bulletins
Security Bulletin: IBM Cloud Pak for Security includes components with multiple known vulnerabilities
7 Jun 202316:53
ibm
IBM Security Bulletins
Security Bulletin: Multiple Security Vulnerabilities may affect IBM Robotic Process Automation for Cloud Pak.
26 Mar 202503:30
ibm
IBM Security Bulletins
Security Bulletin: Multiple Vulnerabilities in CloudPak for Watson AIOPs
26 Mar 202503:32
ibm
IBM Security Bulletins
Security Bulletin: IBM Security Verify Access Appliance includes components with known vulnerabilities
12 Jan 202323:10
ibm
IBM Security Bulletins
Security Bulletin: IBM Watson Speech Services Cartridge for IBM Cloud Pak for Data is vulnerable to spoofing attacks in GnuPG (CVE-2022-34903)
31 Mar 202316:59
ibm
IBM Security Bulletins
Security Bulletin: IBM MQ Operator and Queue manager container images are vulnerable to multiple vulnerabilities from containerd, gnupg2, runc and IBM WebSphere Application Server Liberty
20 Oct 202212:19
ibm
IBM Security Bulletins
Security Bulletin: Multiple Vulnerabilities in base image packages affect IBM Voice Gateway
27 Oct 202218:15
ibm
ATTACKERKB
CVE-2022-34903
1 Jul 202222:15
attackerkb
Tenable Nessus
Amazon Linux 2022 : gnupg2, gnupg2-minimal, gnupg2-smime (ALAS2022-2022-126)
6 Sep 202200:00
nessus
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504908);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/17");

  script_cve_id("CVE-2022-34903");
  script_xref(name:"ICSA", value:"24-046-11");

  script_name(english:"Siemens Ruggedcom ROX Improper Neutralization of Special Elements in Output Used by a Downstream Component (CVE-2022-34903)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"GnuPG through 2.3.6, in unusual situations where an attacker possesses
any secret-key information from a victim's keyring and other
constraints (e.g., use of GPGME) are met, allows signature forgery via
injection into the status line.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-806742.pdf");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-202008.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997648/");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109826613/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-11");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released update V2.4 for SCALANCE X-300 and recommends updating to the latest version.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-806742 in HTML and CSAF.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-34903");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_cwe_id(74);

  script_set_attribute(attribute:"vuln_publication_date", value:"2024/02/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2024/02/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/01/09");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:2.4");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:2.4");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_xch328_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
    "cpe:/o:siemens:scalance_xcm324_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
    "cpe:/o:siemens:scalance_xcm328_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
    "cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
    "cpe:/o:siemens:scalance_xcm332_firmware:2.4" :
        {"versionEndExcluding" : "2.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

17 Feb 2026 00:00Current
7.3High risk
Vulners AI Score7.3
CVSS 25.8
CVSS 3.16.5
EPSS0.02569
7