Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2022-29562.NASL
HistorySep 14, 2023 - 12:00 a.m.

Siemens RUGGEDCOM ROX Improper Input Validation (CVE-2022-29562)

2023-09-1400:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
5
siemens
ruggedcom rox
devices
v2.16.0
input validation
vulnerability
http
remote attacker
tenable.ot

5.3 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

LOW

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

5.7 Medium

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

32.4%

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501625);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id("CVE-2022-29562");

  script_name(english:"Siemens RUGGEDCOM ROX Improper Input Validation (CVE-2022-29562)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All
versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0),
RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500
(All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions <
V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX
RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions <
V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX
RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions <
V2.16.0). Affected devices do not properly handle malformed HTTP
packets. This could allow an unauthenticated remote attacker to send a
malformed HTTP packet causing certain functions to fail in a
controlled manner.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-194-01");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

​Siemens recommends users update the product to the following versions:

- ​Update to V2.16.0 or later version

​As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the
environment according to Siemens' operational guidelines for Industrial Security, and to follow the recommendations in
the product manuals. Additional information on Industrial Security by Siemens can be found at:
https://www.siemens.com/industrialsecurity

​For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens
ProductCERT: https://www.siemens.com/cert/advisories

​As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

​Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

​For more information see the associated Siemens security advisory SSA-146325 in HTML and CSAF.

​");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-29562");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/07/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/07/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/14");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
siemensruggedcom_rox_rx1500_firmwarecpe:/o:siemens:ruggedcom_rox_rx1500_firmware
siemensruggedcom_rox_rx1501_firmwarecpe:/o:siemens:ruggedcom_rox_rx1501_firmware
siemensruggedcom_rox_rx1510_firmwarecpe:/o:siemens:ruggedcom_rox_rx1510_firmware
siemensruggedcom_rox_rx1511_firmwarecpe:/o:siemens:ruggedcom_rox_rx1511_firmware
siemensruggedcom_rox_rx1512_firmwarecpe:/o:siemens:ruggedcom_rox_rx1512_firmware
siemensruggedcom_rox_rx1524_firmwarecpe:/o:siemens:ruggedcom_rox_rx1524_firmware
siemensruggedcom_rox_rx1536_firmwarecpe:/o:siemens:ruggedcom_rox_rx1536_firmware
siemensruggedcom_rox_rx5000_firmwarecpe:/o:siemens:ruggedcom_rox_rx5000_firmware
siemensruggedcom_rox_mx5000_firmwarecpe:/o:siemens:ruggedcom_rox_mx5000_firmware
siemensruggedcom_rox_mx5000re_firmwarecpe:/o:siemens:ruggedcom_rox_mx5000re_firmware
Rows per page:
1-10 of 111

5.3 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

LOW

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

5.7 Medium

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

32.4%

Related for TENABLE_OT_SIEMENS_CVE-2022-29562.NASL