Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2022-28328.NASL
HistoryApr 11, 2023 - 12:00 a.m.

Siemens SCALANCE W1700 Improper Input Validation (CVE-2022-28328)

2023-04-1100:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
12
siemens scalance w1700
input validation
cve-2022-28328
scalance w1788-1 m12
scalance w1788-2 eec m12
scalance w1788-2 m12
scalance w1788-2ia m12
denial of service
multicast llc frames
tenable.ot
vulnerability

0.001 Low

EPSS

Percentile

38.6%

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501044);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id("CVE-2022-28328");

  script_name(english:"Siemens SCALANCE W1700 Improper Input Validation (CVE-2022-28328)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in SCALANCE W1788-1 M12 (All
versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0),
SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12
(All versions < V3.0.0). Affected devices do not properly handle
malformed Multicast LLC frames. This could allow an attacker to
trigger a denial of service condition.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-392912.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-08");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens recommends installing the following software updates to address these vulnerabilities.

- Update SCALANCE W1788-1 M12 to Version 3.0.0 or later
- Update SCALANCE W1788-2 EEC M12 to Version 3.0.0 or later
- Update SCALANCE W1788-2 M12 to Version 3.0.0 or later
- Update SCALANCE W1788-2IA M12 to Version 3.0.0 or later

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment
according to SiemensҀ™ operational guidelines for industrial security and to follow the recommendations in the product
manuals.

Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

For additional information, please refer to Siemens Security Advisory SSA-392912");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-28328");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/04/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/04/12");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/04/11");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1788-1_m12_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1788-2_eec_m12_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1788-2_m12_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_w1788-2ia_m12_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_w1788-2ia_m12_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW"},
    "cpe:/o:siemens:scalance_w1788-2_m12_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW"},
    "cpe:/o:siemens:scalance_w1788-2_eec_m12_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW"},
    "cpe:/o:siemens:scalance_w1788-1_m12_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "SCALANCEW"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemensscalance_w1788-1_m12_firmwarecpe:/o:siemens:scalance_w1788-1_m12_firmware
siemensscalance_w1788-2_eec_m12_firmwarecpe:/o:siemens:scalance_w1788-2_eec_m12_firmware
siemensscalance_w1788-2_m12_firmwarecpe:/o:siemens:scalance_w1788-2_m12_firmware
siemensscalance_w1788-2ia_m12_firmwarecpe:/o:siemens:scalance_w1788-2ia_m12_firmware

0.001 Low

EPSS

Percentile

38.6%

Related for TENABLE_OT_SIEMENS_CVE-2022-28328.NASL