CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
COMPLETE
AV:N/AC:L/Au:N/C:N/I:N/A:C
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
Percentile
42.6%
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501629);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");
script_cve_id("CVE-2021-41546");
script_xref(name:"ICSA", value:"21-287-08");
script_name(english:"Siemens RUGGEDCOM ROX Devices Uncontrolled Resource Consumption (CVE-2021-41546)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All
versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1),
RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501
(All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions <
V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX
RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions <
V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX
RX5000 (All versions < V2.14.1). Affected devices write crashdumps
without checking if enough space is available on the filesystem. Once
the crashdump fills the entire root filesystem, affected devices fail
to boot successfully. An attacker can leverage this vulnerability to
cause a permanent Denial-of-Service.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-173565.pdf");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-21-287-08");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has released updates for the affected products and recommends updating to the latest versions:
- Update to v2.14.1 or later version.
- Restrict access to the affected systems, especially to Port 443/TCP, to trusted IP addresses only.
As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the
environment according to SiemensΓ’ΒΒ operational guidelines for industrial security, and to follow the recommendations in
the product manuals.
For additional information, please refer to Siemens Security Advisory SSA-173565");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-41546");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(770);
script_set_attribute(attribute:"vuln_publication_date", value:"2021/10/12");
script_set_attribute(attribute:"patch_publication_date", value:"2021/10/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/14");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"current");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
{"versionEndExcluding" : "2.14.1", "family" : "RuggedCom"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
COMPLETE
AV:N/AC:L/Au:N/C:N/I:N/A:C
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
Percentile
42.6%