Lucene search

K
nessusThis script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2021-41089.NASL
HistoryJan 15, 2024 - 12:00 a.m.

Siemens SCALANCE LPE9403 Improper Preservation of Permissions (CVE-2021-41089)

2024-01-1500:00:00
This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
13
siemens scalance lpe9403
vulnerability
file permissions
unix
docker engine
tenable.ot
cve-2021-41089
cisa
industrial security

6.8 Medium

AI Score

Confidence

High

A vulnerability was found in Moby (Docker Engine) where attempting to copy files using β€˜docker cp’ into a specially-crafted container can result in Unix file permission changes for existing files in the host’s filesystem, widening access to others. This bug does not directly allow files to be read, modified, or executed without an additional cooperating process.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501885);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/30");

  script_cve_id("CVE-2021-41089");

  script_name(english:"Siemens SCALANCE LPE9403 Improper Preservation of Permissions (CVE-2021-41089)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability was found in Moby (Docker Engine) where attempting to copy files using 'docker cp' 
into a specially-crafted container can result in Unix file permission changes for existing files in the 
host's filesystem, widening access to others. This bug does not directly allow files to be read, modified, 
or executed without an additional cooperating process.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-09");
  script_set_attribute(attribute:"see_also", value:"https://cwe.mitre.org/data/definitions/281.html");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens recommends users of the affected product update to Version 2.0 or later.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to SiemensҀ™
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see Siemens Security Advisory SSA-222547");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:M/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-41089");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/04/10");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/06/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/01/15");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9403_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_lpe9403_firmware" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCE", "orderNumbers" : ["6GK5998-3GS00-2AC2"]}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
siemensscalance_lpe9403_firmwarecpe:/o:siemens:scalance_lpe9403_firmware