Lucene search
+L

Siemens Ruggedcom ROX Incorrect Authorization (CVE-2021-35567)

🗓️ 09 Jan 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 9 Views

Flaw in Java Standard Edition and Oracle GraalVM lets a Kerberos attacker with user interaction access data

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504907);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/17");

  script_cve_id("CVE-2021-35567");

  script_name(english:"Siemens Ruggedcom ROX Incorrect Authorization (CVE-2021-35567)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Vulnerability in the Java SE, Oracle GraalVM Enterprise Edition
product of Oracle Java SE (component: Libraries). Supported versions
that are affected are Java SE: 8u301, 11.0.12, 17; Oracle GraalVM
Enterprise Edition: 20.3.3 and 21.2.0. Easily exploitable
vulnerability allows low privileged attacker with network access via
Kerberos to compromise Java SE, Oracle GraalVM Enterprise Edition.
Successful attacks require human interaction from a person other than
the attacker and while the vulnerability is in Java SE, Oracle GraalVM
Enterprise Edition, attacks may significantly impact additional
products. Successful attacks of this vulnerability can result in
unauthorized access to critical data or complete access to all Java
SE, Oracle GraalVM Enterprise Edition accessible data. Note: This
vulnerability applies to Java deployments, typically in clients
running sandboxed Java Web Start applications or sandboxed Java
applets, that load and run untrusted code (e.g., code that comes from
the internet) and rely on the Java sandbox for security. This
vulnerability can also be exploited by using APIs in the specified
Component, e.g., through a web service which supplies data to the
APIs. CVSS 3.1 Base Score 6.8 (Confidentiality impacts). CVSS Vector:
(CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N).

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-202008.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997648/");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:S/C:C/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-35567");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(863);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/12/09");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/12/09");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/01/09");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.17.0", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation