Siemens RUGGEDCOM ROX II Cross-Site Request Forgery (CVE-2020-28398)
| Reporter | Title | Published | Views | Family All 12 |
|---|---|---|---|---|
| The vulnerability in the web interface of the microprogramming software for routing and switching platforms RUGGEDCOM ROX MX5000, RUGGEDCOM ROX MX5000RE, and RUGGEDCOM ROX RX1400 allows a attacker to perform a CSRF attack. | 6 Feb 202500:00 | – | bdu_fstec | |
| CVE-2020-28398 | 10 Dec 202416:38 | – | circl | |
| Siemens RUGGEDCOM 安全漏洞 | 10 Dec 202400:00 | – | cnnvd | |
| Siemens RUGGEDCOM ROX II Cross-Site Request Forgery Vulnerability | 11 Dec 202400:00 | – | cnvd | |
| CVE-2020-28398 | 10 Dec 202413:53 | – | cve | |
| CVE-2020-28398 | 10 Dec 202413:53 | – | cvelist | |
| EUVD-2020-20857 | 7 Oct 202500:30 | – | euvd | |
| Siemens RUGGEDCOM ROX II | 10 Dec 202400:00 | – | ics | |
| Vulnerabilities fixed in Siemens products | 10 Dec 202419:34 | – | ncsc | |
| CVE-2020-28398 | 10 Dec 202414:15 | – | nvd |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502805);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");
script_cve_id("CVE-2020-28398");
script_xref(name:"ICSA", value:"24-347-03");
script_name(english:"Siemens RUGGEDCOM ROX II Cross-Site Request Forgery (CVE-2020-28398)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The CLI feature in the web interface of affected devices is vulnerable
to cross-site request forgery (CSRF). This could allow an
attacker to read or modify the device configuration by tricking an
authenticated legitimate user into accessing a malicious link.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-384652.html");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109821187/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-347-03");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:
- All affected products: Only access links from trusted sources while authenticated in web interface of the affected
devices
- All affected products: Update to V2.16.0 or later version
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.
Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.
For more information see the associated Siemens security advisory SSA-384652 in HTML and CSAF.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-28398");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(352);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/12/10");
script_set_attribute(attribute:"patch_publication_date", value:"2024/12/10");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/12/18");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2024-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1524_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx1536_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"},
"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
{"versionEndExcluding" : "2.16.0", "family" : "RuggedCom"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
14 Feb 2026 00:00Current
5.3Medium risk
Vulners AI Score5.3
CVSS 48.6
CVSS 3.18.8
EPSS0.00204
SSVC