Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2019-12261.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Siemens Improper Restriction of Operations Within the Bounds of a Memory Buffer in Wind River VxWorks (CVE-2019-12261)

2022-02-0700:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
12

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.6 High

AI Score

Confidence

High

0.065 Low

EPSS

Percentile

93.8%

Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500203);
  script_version("1.12");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/11/15");

  script_cve_id("CVE-2019-12261");
  script_xref(name:"CEA-ID", value:"CEA-2019-0679");

  script_name(english:"Siemens Improper Restriction of Operations Within the Bounds of a Memory Buffer in Wind River VxWorks (CVE-2019-12261)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET
security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.  

This plugin only works
with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf");
  script_set_attribute(attribute:"see_also", value:"https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009");
  script_set_attribute(attribute:"see_also", value:"https://support2.windriver.com/index.php?page=security-notices");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-19-274-01");
  # https://support2.windriver.com/index.php?page=cve&on=view&id=CVE-2019-12261
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?06266588");
  script_set_attribute(attribute:"see_also", value:"https://security.netapp.com/advisory/ntap-20190802-0001/");
  # https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c7d3d59d");
  script_set_attribute(attribute:"see_also", value:"https://support.f5.com/csp/article/K41190253");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.oracle.com/security-alerts/cpuoct2020.html");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-19-211-01");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Wind River has produced controls and patches to mitigate the reported vulnerabilities. To obtain patches, email
[email protected] and indicate the VxWorks major version for which you need source patches.

For more detailed information on the vulnerabilities and the mitigating controls, please see the Wind River advisory at:
https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/

Additional vendors affected by the reported vulnerabilities have also released security advisories related to their
affected products. Those advisories are as follows:

Rockwell Automation (login required) - https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1088561

Xerox - https://security.business.xerox.com/en-us/news/wind-river-vxworks-ipnet-tcp-ip-stack-vulnerabilities/

DrÀger Ҁ“ https://static.draeger.com/security

Schneider Electric Ҁ“ https://www.se.com/ww/en/download/document/SESB-2019-214-01/");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-12261");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(120);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/08/09");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/08/09");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siprotec_5_cp300_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:siprotec_5_cp300_firmware" :
        {"versionEndExcluding" : "8.01", "family" : "Siprotec5"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
siemenssiprotec_5_cp300_firmwarecpe:/o:siemens:siprotec_5_cp300_firmware

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.6 High

AI Score

Confidence

High

0.065 Low

EPSS

Percentile

93.8%