Lucene search

K
nessusThis script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2018-18508.NASL
HistorySep 14, 2023 - 12:00 a.m.

Siemens RUGGEDCOM ROX II Null Pointer Dereference (CVE-2018-18508)

2023-09-1400:00:00
This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
20
siemens
ruggedcom
vulnerability
null pointer dereference
nss
denial of service
ot asset
tenable
cisa

CVSS2

4.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:N/I:N/A:P

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

AI Score

7

Confidence

High

EPSS

0.002

Percentile

60.9%

In Network Security Services (NSS) before 3.36.7 and before 3.41.1, a malformed signature can cause a crash due to a null dereference, resulting in a Denial of Service.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501626);
  script_version("1.4");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");

  script_cve_id("CVE-2018-18508");
  script_xref(name:"ICSA", value:"21-040-04");

  script_name(english:"Siemens RUGGEDCOM ROX II Null Pointer Dereference (CVE-2018-18508)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"In Network Security Services (NSS) before 3.36.7 and before 3.41.1, a
malformed signature can cause a crash due to a null dereference,
resulting in a Denial of Service.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf");
  # https://developer.mozilla.org/en-US/docs/Mozilla/Projects/NSS/NSS_3.36.7_release_notes
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?2f028e49");
  # https://developer.mozilla.org/en-US/docs/Mozilla/Projects/NSS/NSS_3.41.1_release_notes
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?0c4af3e3");
  script_set_attribute(attribute:"see_also", value:"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has released the following update and recommends it be applied:

RUGGEDCOM ROX (products listed above): Update to v2.14.0 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

- Disable IPsec unless the feature is required in the network environment. Note that IPsec is disabled by default.

As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the
environment according to SiemensҀ™ operational guidelines for Industrial Security, and follow the recommendations in the
product manuals.

Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity.
For more information see Siemens security advisory SSA-379803");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-18508");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(476);

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/10/22");
  script_set_attribute(attribute:"patch_publication_date", value:"2020/10/22");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/09/14");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_mx5000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1500_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1501_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1510_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1511_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx1512_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rox_rx5000_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rox_mx5000_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1400_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1500_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1501_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1510_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1511_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx1512_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"},
    "cpe:/o:siemens:ruggedcom_rox_rx5000_firmware" :
        {"versionEndExcluding" : "2.14.0", "family" : "RuggedCom"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

CVSS2

4.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:M/Au:N/C:N/I:N/A:P

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

AI Score

7

Confidence

High

EPSS

0.002

Percentile

60.9%