Siemens CP1604 and CP1616 Cleartext Transmission of Sensitive Information (CVE-2018-13808)

2024-02-2000:00:00
This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
4
siemens cp1604
siemens cp1616
cleartext transmission
sensitive information
cve-2018-13808
network access
denial-of-service
tenableot
web server
vulnerable device
vpn network
industrial security
software updates

6.4 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:N/A:P

9.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

9.2 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

54.1%

A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could extract internal communication data or cause a Denial-of-Service condition. Successful exploitation requires network access to a vulnerable device. At the time of advisory publication no public exploitation of this vulnerability was known.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(502002);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/03/04");

  script_cve_id("CVE-2018-13808");

  script_name(english:"Siemens CP1604 and CP1616 Cleartext Transmission of Sensitive Information (CVE-2018-13808)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability has been identified in CP 1604 (All versions), CP 1616
(All versions). An attacker with network access to port 23/tcp could
extract internal communication data or cause a Denial-of-Service
condition. Successful exploitation requires network access to a
vulnerable device. At the time of advisory publication no public
exploitation of this vulnerability was known.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-559174.pdf");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-19-043-06");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens recommends users update to version 2.8.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk: 

- Disable the integrated web server. The web server is disabled in the default settings and its use is optional. Use in
a productive environment is discouraged.
- Restrict access to the device to the internal or VPN network. Further restrict access to the web interface (80/TCP)
and to the telnet port (23/TCP) to trusted IP addresses if possible.
- Do not click on links from unknown sources.

- Fixes for CVE-2018-13808 have also been released in versions v2.5.2.7, v2.6.2.2, and v2.7.2.1.

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the
environment according to SiemensҀ™ operational guidelines for industrial security
(https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the
product manuals.

Additional information on industrial security by Siemens can be found at: 

https://www.siemens.com/industrialsecurity

For more information on these vulnerabilities and associated software updates, please see Siemens security advisory
SSA-559174 on their website:

https://www.siemens.com/cert/advisories");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-13808");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(200);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/04/17");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/04/17");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/02/20");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:cp_1604_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:cp_1616_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:cp_1604_firmware" :
        {"versionEndIncluding" : "2.8", "family" : "NETCP1600"},
    "cpe:/o:siemens:cp_1616_firmware" :
        {"versionEndIncluding" : "2.8", "family" : "NETCP1600"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
siemenscp_1604_firmwarecpe:/o:siemens:cp_1604_firmware
siemenscp_1616_firmwarecpe:/o:siemens:cp_1616_firmware

6.4 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:N/A:P

9.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

9.2 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

54.1%

Related for TENABLE_OT_SIEMENS_CVE-2018-13808.NASL