Siemens SCALANCE, SIMATIC S7-1500 Generation of Error Message Containing Sensitive Information (CVE-2018-12886)

🗓️ 13 Nov 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 6 Views

CVE-2018-12886: GCC stack-protector bypass on ARM targets enables canary bypass.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(504085);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2018-12886");
  script_xref(name:"ICSA", value:"23-080-07");

  script_name(english:"Siemens SCALANCE, SIMATIC S7-1500 Generation of Error Message Containing Sensitive Information (CVE-2018-12886)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"stack_protect_prologue in cfgexpand.c and stack_protect_epilogue in
function.c in GNU Compiler Collection (GCC) 4.1 through 8 (under
certain circumstances) generate instruction sequences when targeting
ARM targets that spill the address of the stack protector guard, which
allows an attacker to bypass the protection of -fstack-protector,
-fstack-protector-all, -fstack-protector-strong, and -fstack-
protector-explicit against stack overflow by controlling what the
stack canary is compared against.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-565386.pdf");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-398330.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109815650/");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109478459/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-07");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

For Scalance devices, Siemens recommends updating the software to v2.0 or later. 

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate
mechanisms. To operate the devices in a protected IT environment, Siemens recommends users configure the environment
according to Siemens' operational guidelines for Industrial Security and to follow the recommendations in the product
manuals. Additional information on Industrial Security by Siemens can be found on the Siemens webpage for Industrial
Security.

For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens
ProductCERT.

For more information, see the associated Siemens security advisory SSA-565386 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-12886");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(209);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/03/14");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/03/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/11/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam763-1_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28eu%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28eu%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum763-1_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28eu%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_wum766-1_%28us%29_firmware:2.0");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_wam763-1_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-7DA0']},
    "cpe:/o:siemens:scalance_wam766-1_%28eu%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DA0']},
    "cpe:/o:siemens:scalance_wam766-1_%28us%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7DB0']},
    "cpe:/o:siemens:scalance_wam766-1_eec_%28eu%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TA0']},
    "cpe:/o:siemens:scalance_wam766-1_eec_%28us%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-7TB0']},
    "cpe:/o:siemens:scalance_wum763-1_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5763-1AL00-3AA0', '6GK5763-1AL00-3DA0']},
    "cpe:/o:siemens:scalance_wum766-1_%28eu%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DA0']},
    "cpe:/o:siemens:scalance_wum766-1_%28us%29_firmware:2.0" :
        {"versionEndExcluding" : "2.0", "family" : "SCALANCEW", "orderNumbers" : ['6GK5766-1GE00-3DB0']},
    "cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6ES7518-4AX00-1AB0', '6ES7518-4FX00-1AC0', '6ES7518-4AX00-1AC0', '6ES7518-4FX00-1AB0']},
    "cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5" :
        {"versionEndExcluding" : "3.1.5", "versionStartIncluding" : "3.1.0", "family" : "S71500", "orderNumbers" : ['6AG1518-4AX00-4AC0']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
7.2High risk
Vulners AI Score7.2
CVSS 26.8
CVSS 38.1
EPSS0.02171
6