Lucene search
K

Siemens SCALANCE X-200RNA Switch Devices Improper Input Validation (CVE-2016-6302)

🗓️ 13 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 10 Views

Siemens SCALANCE X-200RNA Switch devices face a vulnerability due to improper input validation.

Related
Refs
Code
ReporterTitlePublishedViews
Family
IBM Security Bulletins
Security Bulletin: Vulnerabilities in OpenSSL affects IBM Rational ClearCase (CVE-2016-2177, CVE-2016-2178, CVE-2016-2183, CVE-2016-6302, CVE-2016-6303, CVE-2016-6304, CVE-2016-6306)
10 Jul 201808:34
ibm
IBM Security Bulletins
Security Bulletin: Multiple Security vulnerabilities fixed in IBM Security Privileged Identity Manager
16 Jun 201821:59
ibm
IBM Security Bulletins
Security Bulletin: IBM Security Guardium is affected by OpenSSL Security Advisory [22 Sep 2016] and [26 Sep 2016] vulnerabilities (multiple CVEs)
16 Jun 201821:47
ibm
IBM Security Bulletins
Security Bulletin: Vulnerabilities in OpenSSL affect IBM SmartCloud Entry
19 Jul 202000:49
ibm
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities in OpenSSL affect IBM Image Construction and Composition Tool.
15 Jun 201807:06
ibm
IBM Security Bulletins
Security Bulletin: Vulnerabilities in OpenSSL affect IBM Aspera Enterprise Server, Connect Server, Point to Point Client, Desktop Client, Faspstream, Cargo, and Sync (CVE-2016-6302 CVE-2016-6304 CVE-2016-6303 CVE-2016-2182 CVE-2016-2177 CVE-2016-2178 ...)
15 Jun 201807:08
ibm
IBM Security Bulletins
Security Bulletin: Vulnerabilities in OpenSSL affects IBM Tivoli Composite Application Manager for Transactions
17 Jun 201815:39
ibm
IBM Security Bulletins
Security Bulletin: Fabric OS firmware for Brocade 8Gb SAN Switch Module for BladeCenter is affected by vulnerabilities in OpenSSL and OpenSSH
16 Jun 201915:15
ibm
IBM Security Bulletins
Security Bulletin: IBM Security Guardium is affected by Using Components with Known Vulnerabilities
16 Jun 201822:03
ibm
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities in OpenSSL affect IBM Workload Scheduler
17 Jun 201815:32
ibm
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503115);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/13");

  script_cve_id("CVE-2016-6302");
  script_xref(name:"ICSA", value:"22-349-21");

  script_name(english:"Siemens SCALANCE X-200RNA Switch Devices Improper Input Validation (CVE-2016-6302)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The tls_decrypt_ticket function in ssl/t1_lib.c in OpenSSL before
1.1.0 does not consider the HMAC size during validation of the ticket
length, which allows remote attackers to cause a denial of service via
a ticket that is too short.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814809/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-6302");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(20);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
    "cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

13 Mar 2025 00:00Current
7.4High risk
Vulners AI Score7.4
CVSS 25
CVSS 37.5
EPSS0.26441
10