#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503101);
script_version("1.1");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/13");
script_cve_id("CVE-2016-10011");
script_xref(name:"ICSA", value:"22-349-21");
script_name(english:"Siemens SCALANCE X-200RNA Switch Devices Improper Access Control (CVE-2016-10011)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"authfile.c in sshd in OpenSSH before 7.4 does not properly consider
the effects of realloc on buffer contents, which might allow local
users to obtain sensitive private-key information by leveraging access
to a privilege-separated child process.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-676336.pdf");
script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814809/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109817790/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109801131/");
script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109808359/");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-10011");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(20, 284);
script_set_attribute(attribute:"vuln_publication_date", value:"2021/09/14");
script_set_attribute(attribute:"patch_publication_date", value:"2021/09/14");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/13");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x200-4p_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x201-3p_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x201-3p_irt_pro_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2p_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x202-2p_irt_pro_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2fm_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ld_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ld_ts_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204-2ts_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204irt_pro_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x206-1_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x206-1ld_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x208pro_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x212-2ld_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x216_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x224_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%28230v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%28230v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%2824v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%2824v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x304-2fe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x306-1ld_fe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%28230v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%28230v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%2824v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%2824v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%2c_coated%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-3_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x307-3ld_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2ld_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2lh%2b_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2lh_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_poe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x308-2m_ts_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x310_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x310fe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x320-1-2ld_fe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x320-1_fe_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x408-2_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf201-3p_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf202-2p_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204-2ba_irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf204irt_firmware:5.5.2");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf206-1_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xf208_firmware:5.2.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-12m_ts_%2824v%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_rear%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr324-4m_poe_ts_%2824v%2c_ports_on_front%29_firmware:4.1.4");
script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:siplus_net_scalance_x308-2_firmware:4.1.4");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Siemens");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Siemens');
var asset = tenable_ot::assets::get(vendor:'Siemens');
var vuln_cpes = {
"cpe:/o:siemens:scalance_x200-4p_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5200-4AH00-2BA3']},
"cpe:/o:siemens:scalance_x201-3p_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3BH00-2BA3']},
"cpe:/o:siemens:scalance_x201-3p_irt_pro_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3JR00-2BA6']},
"cpe:/o:siemens:scalance_x202-2irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BB00-2BA3']},
"cpe:/o:siemens:scalance_x202-2p_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BH00-2BA3']},
"cpe:/o:siemens:scalance_x202-2p_irt_pro_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2JR00-2BA6']},
"cpe:/o:siemens:scalance_x204irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0BA00-2BA3']},
"cpe:/o:siemens:scalance_x204irt_pro_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0JA00-2BA6']},
"cpe:/o:siemens:scalance_xf201-3p_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5201-3BH00-2BD2']},
"cpe:/o:siemens:scalance_xf202-2p_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5202-2BH00-2BD2']},
"cpe:/o:siemens:scalance_xf204-2ba_irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-2AA00-2BD2']},
"cpe:/o:siemens:scalance_xf204irt_firmware:5.5.2" :
{"versionEndExcluding" : "5.5.2", "family" : "SCALANCEX200IRT", "orderNumbers" : ['6GK5204-0BA00-2BF2']},
"cpe:/o:siemens:scalance_x204-2_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB10-2AA3']},
"cpe:/o:siemens:scalance_x204-2fm_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB11-2AA3']},
"cpe:/o:siemens:scalance_x204-2ld_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BC10-2AA3']},
"cpe:/o:siemens:scalance_x204-2ld_ts_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BC10-2CA2']},
"cpe:/o:siemens:scalance_x204-2ts_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-2BB10-2CA2']},
"cpe:/o:siemens:scalance_x206-1_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BB10-2AA3']},
"cpe:/o:siemens:scalance_x206-1ld_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BC10-2AA3']},
"cpe:/o:siemens:scalance_x208pro_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5208-0HA10-2AA6']},
"cpe:/o:siemens:scalance_x212-2ld_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5212-2BC00-2AA3']},
"cpe:/o:siemens:scalance_x216_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5216-0BA00-2AA3']},
"cpe:/o:siemens:scalance_x224_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5224-0BA00-2AA3']},
"cpe:/o:siemens:scalance_xf204_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2AF2']},
"cpe:/o:siemens:scalance_xf206-1_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5206-1BC00-2AF2']},
"cpe:/o:siemens:scalance_xf208_firmware:5.2.5" :
{"versionEndExcluding" : "5.2.5", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5208-0BA00-2AF2']},
"cpe:/o:siemens:scalance_x302-7_eec_%28230v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-3GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%28230v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-3EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%2824v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-1GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%2824v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-1EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-4GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_230v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-4EA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-2GA3']},
"cpe:/o:siemens:scalance_x302-7_eec_%282x_24v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5302-7GD00-2EA3']},
"cpe:/o:siemens:scalance_x304-2fe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5304-2BD00-2AA3']},
"cpe:/o:siemens:scalance_x306-1ld_fe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5306-1BF00-2AA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%28230v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-3GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%28230v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-3EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%2824v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-1GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%2824v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-1EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-4GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_230v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-4EA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%2c_coated%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-2GA3']},
"cpe:/o:siemens:scalance_x307-2_eec_%282x_24v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-2FD00-2EA3']},
"cpe:/o:siemens:scalance_x307-3_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-3BL00-2AA3', '6GK5307-3BL10-2AA3']},
"cpe:/o:siemens:scalance_x307-3ld_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5307-3BM10-2AA3', '6GK5307-3BM00-2AA3']},
"cpe:/o:siemens:scalance_x308-2_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FL00-2AA3', '6GK5308-2FL10-2AA3']},
"cpe:/o:siemens:scalance_x308-2ld_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FM00-2AA3', '6GK5308-2FM10-2AA3']},
"cpe:/o:siemens:scalance_x308-2lh_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FN10-2AA3', '6GK5308-2FN00-2AA3']},
"cpe:/o:siemens:scalance_x308-2lh%2b_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2FP00-2AA3', '6GK5308-2FP10-2AA3']},
"cpe:/o:siemens:scalance_x308-2m_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2GG10-2AA2', '6GK5308-2GG00-2AA2']},
"cpe:/o:siemens:scalance_x308-2m_poe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2QG00-2AA2', '6GK5308-2QG10-2AA2']},
"cpe:/o:siemens:scalance_x308-2m_ts_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5308-2GG10-2CA2', '6GK5308-2GG00-2CA2']},
"cpe:/o:siemens:scalance_x310_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5310-0FA00-2AA3', '6GK5310-0FA10-2AA3']},
"cpe:/o:siemens:scalance_x310fe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5310-0BA10-2AA3', '6GK5310-0BA00-2AA3']},
"cpe:/o:siemens:scalance_x320-1_fe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5320-1BD00-2AA3']},
"cpe:/o:siemens:scalance_x320-1-2ld_fe_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5320-3BF00-2AA3']},
"cpe:/o:siemens:scalance_x408-2_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX400", "orderNumbers" : ['6GK5408-2FD00-2AA2']},
"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG00-3AR2', '6GK5324-0GG10-3AR2']},
"cpe:/o:siemens:scalance_xr324-12m_%28230v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG00-3HR2', '6GK5324-0GG10-3HR2']},
"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG00-1AR2', '6GK5324-0GG10-1AR2']},
"cpe:/o:siemens:scalance_xr324-12m_%2824v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-1HR2', '6GK5324-0GG00-1HR2']},
"cpe:/o:siemens:scalance_xr324-12m_ts_%2824v%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-0GG10-1CR2', '6GK5324-0GG00-1CR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-3ER2', '6GK5324-4GG00-3ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%28100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-3JR2', '6GK5324-4GG00-3JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-1ER2', '6GK5324-4GG00-1ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%2824v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-1JR2', '6GK5324-4GG00-1JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-4ER2', '6GK5324-4GG00-4ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_100-240vac%2f60-250vdc%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-4JR2', '6GK5324-4GG00-4JR2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-2ER2', '6GK5324-4GG00-2ER2']},
"cpe:/o:siemens:scalance_xr324-4m_eec_%282x_24v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4GG10-2JR2', '6GK5324-4GG00-2JR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-3AR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%28230v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-3HR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-1AR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_%2824v%2c_ports_on_rear%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-1HR2']},
"cpe:/o:siemens:scalance_xr324-4m_poe_ts_%2824v%2c_ports_on_front%29_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-4QG00-1CR2']},
"cpe:/o:siemens:siplus_net_scalance_x308-2_firmware:4.1.4" :
{"versionEndExcluding" : "4.1.4", "family" : "SCALANCEX300", "orderNumbers" : ['6AG1308-2FL10-4AA3']},
"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7" :
{"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7" :
{"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7" :
{"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7" :
{"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7" :
{"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation