Lucene search
+L

Siemens SCALANCE X-200RNA Switch Devices Incorrect Calculation (CVE-2015-1794)

🗓️ 13 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 9 Views

Siemens SCALANCE X-200RNA devices have a vulnerability causing denial of service (CVE-2015-1794).

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503072);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/13");

  script_cve_id("CVE-2015-1794");
  script_xref(name:"ICSA", value:"22-349-21");

  script_name(english:"Siemens SCALANCE X-200RNA Switch Devices Incorrect Calculation (CVE-2015-1794)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The ssl3_get_key_exchange function in ssl/s3_clnt.c in OpenSSL 1.0.2
before 1.0.2e allows remote servers to cause a denial of service
(segmentation fault) via a zero p value in an anonymous Diffie-Hellman
(DH) ServerKeyExchange message.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814809/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2015-1794");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(682);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
    "cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

13 Mar 2025 00:00Current
7.3High risk
Vulners AI Score7.3
CVSS 25
EPSS0.0498
9