nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2023-5985.NASL
HistoryDec 15, 2023 - 12:00 a.m.

Schneider PowerLogic ION8650,ION8800 Cross-site Scripting (CVE-2023-5985)

2023-12-1500:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
2
schneider powerlogic
ion8650
ion8800
cross-site scripting
cve-2023-5985
improper neutralization
tenable.ot

4.8 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

7.1 High

AI Score

Confidence

Low

0.0004 Low

EPSS

Percentile

14.2%

A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501835);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/12/18");

  script_cve_id("CVE-2023-5985");

  script_name(english:"Schneider PowerLogic ION8650,ION8800 Cross-site Scripting (CVE-2023-5985)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-79 Improper Neutralization of Input During Web Page Generation
vulnerability exists that could cause compromise of a user's browser
when an attacker with admin privileges has modified system values.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?e74acebf");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:P/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-5985");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/11/15");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/11/15");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/12/15");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:ion8650_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:ion8800_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:ion8650_firmware" :
        {"family" : "ION"},
    "cpe:/o:schneider-electric:ion8800_firmware" :
        {"family" : "ION"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
schneider-electricion8650_firmwarecpe:/o:schneider-electric:ion8650_firmware
schneider-electricion8800_firmwarecpe:/o:schneider-electric:ion8800_firmware

4.8 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

7.1 High

AI Score

Confidence

Low

0.0004 Low

EPSS

Percentile

14.2%

Related for TENABLE_OT_SCHNEIDER_CVE-2023-5985.NASL