Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2021-22714.NASL
HistoryJul 21, 2022 - 12:00 a.m.

Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22714)

2022-07-2100:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
21

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

0.005 Low

EPSS

Percentile

76.3%

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

  • A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution. (CVE-2021-22714)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500665);
  script_version("1.6");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/10/17");

  script_cve_id("CVE-2021-22714");

  script_name(english:"Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22714)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic
ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote
code execution.

  - A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in
    PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to
    reboot or allow for remote code execution. (CVE-2021-22714)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2021-068-02");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-22714");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(119);

  script_set_attribute(attribute:"vuln_publication_date", value:"2021/03/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2021/03/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/07/21");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7400_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion9000_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_pm8000_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:powerlogic_ion7400_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "ION"},
    "cpe:/o:schneider-electric:powerlogic_pm8000_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "PowerLogicPM"},
    "cpe:/o:schneider-electric:powerlogic_ion9000_firmware" :
        {"versionEndExcluding" : "3.0.0", "family" : "ION"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
schneider-electricpowerlogic_ion7400_firmwarecpe:/o:schneider-electric:powerlogic_ion7400_firmware
schneider-electricpowerlogic_ion9000_firmwarecpe:/o:schneider-electric:powerlogic_ion9000_firmware
schneider-electricpowerlogic_pm8000_firmwarecpe:/o:schneider-electric:powerlogic_pm8000_firmware

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

0.005 Low

EPSS

Percentile

76.3%