7.5 High
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
9.8 High
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
0.005 Low
EPSS
Percentile
76.3%
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(500665);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2023/10/17");
script_cve_id("CVE-2021-22714");
script_name(english:"Schneider Electric PowerLogic Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22714)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic
ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote
code execution.
- A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in
PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to
reboot or allow for remote code execution. (CVE-2021-22714)
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2021-068-02");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-22714");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(119);
script_set_attribute(attribute:"vuln_publication_date", value:"2021/03/11");
script_set_attribute(attribute:"patch_publication_date", value:"2021/03/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/07/21");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion9000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_pm8000_firmware");
script_set_attribute(attribute:"generated_plugin", value:"current");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:powerlogic_ion7400_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_pm8000_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "PowerLogicPM"},
"cpe:/o:schneider-electric:powerlogic_ion9000_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "ION"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Vendor | Product | Version | CPE |
---|---|---|---|
schneider-electric | powerlogic_ion7400_firmware | cpe:/o:schneider-electric:powerlogic_ion7400_firmware | |
schneider-electric | powerlogic_ion9000_firmware | cpe:/o:schneider-electric:powerlogic_ion9000_firmware | |
schneider-electric | powerlogic_pm8000_firmware | cpe:/o:schneider-electric:powerlogic_pm8000_firmware |
7.5 High
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:P/I:P/A:P
9.8 High
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
0.005 Low
EPSS
Percentile
76.3%